Medical devices equipped with position sensors enable applications like image guided surgical interventions, reconstruction of three-dimensional 3D ultrasound (US) images, and virtual or augmented reality systems. The acquisition of three-dimensional position data in real time is one of the key technologies in this field. The systematic distortions induced by various metals, surgical tools, and US scan probes in different commercial electromagnetic tracking systems were assessed in the presented work. A precise nonmetallic six degree-of-freedom measurement rack was built that allowed a quantitative comparison of different electromagnetic trackers. Also, their performance in the presence of large metallic structures was quantified in a phantom study on an acrylic skull model in an operating room (OR). The trackers used were alternating current (ac) and direct current (dc) based systems. The ac trackers were, on average, distorted by 0.7 mm and 0.5 degree by metallic objects positioned at a distance greater than 120 mm between the geometrical center of the sample and the sensor. In the OR environment, the ac system exhibits mean errors of 3.2 +/- 2.4 mm and 2.9 degrees +/- 1.9 degrees. The dc trackers are more sensitive to distortions caused by ferromagnetic materials (averaged value: 1.6 mm and 0.5 degree beyond a distance of 120 mm). The dc tracker shows no distortions from other conductive materials but was less accurate in the OR environment (typical error: 6.4 +/- 2.5 mm and 4.9 degrees +/- 2.0 degrees). At distances smaller than approximately 100 mm between sample and sensor error increases quickly. It is also apparent from our measurements that the influence of US scan probes is governed by their shielding material. The results show that surgical instruments not containing conductive material are to be preferred when using an ac tracker. Nonferromagnetic instruments should be used with dc trackers. Static distortions caused by the OR environment have to be compensated by precise calibration methods.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.598425DOI Listing

Publication Analysis

Top Keywords

+/- degrees
16
systematic distortions
8
scan probes
8
sample sensor
8
degrees +/-
8
distortions caused
8
trackers
5
distortions magnetic
4
magnetic position
4
position digitizers
4

Similar Publications

Background: Microsurgery demands an intensive period of skill acquisition due to its inherent complexity. The development and implementation of innovative training methods are essential for enhancing microsurgical outcomes. This study aimed to evaluate the impact of a simulation training program on the clinical results of fingertip replantation surgeries.

View Article and Find Full Text PDF

Pitch variation of the fundamental frequency (F0) is critical to speech understanding, especially in noisy environments. Degrading the F0 contour reduces behaviorally measured speech intelligibility, posing greater challenges for tonal languages like Mandarin Chinese where the F0 pattern determines semantic meaning. However, neural tracking of Mandarin speech with degraded F0 information in noisy environments remains unclear.

View Article and Find Full Text PDF

Importance: Patients undergoing unplanned abdominal surgical procedures are at increased risk of surgical site infection (SSI). It is not known if incisional negative pressure wound therapy (iNPWT) can reduce SSI rates in this setting.

Objective: To evaluate the effectiveness of iNPWT in reducing the rate of SSI in adults undergoing emergency laparotomy with primary skin closure.

View Article and Find Full Text PDF

Hip involvement is a common condition in about one-third of patients with axial spondyloarthritis (axSpA). We assessed the incidence of possible factors that predispose patients to limited flexion after total hip arthroplasty (THA) for the treatment of axSpA. We retrospectively reviewed 516 patients with axSpA (759 hips) who underwent THA.

View Article and Find Full Text PDF

Purpose: The objective of this study is to evaluate the impact of pelvic floor physical therapy (PFPT) on symptoms and quality of life in women who experienced third- and fourth-degree perineal tears (Obstetric Anal Sphincter Injuries, OASIS) during childbirth. OASIS can lead to anal incontinence and dyspareunia, having important implications regarding the quality of life and health of women but, unfortunately, there is no standard practice for postpartum care following OASIS.

Methods: In this retrospective observational study, patients diagnosed with OASIS between January 2016 and June 2023 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!