Cavitary electrograms previously were measured from multiple directions simultaneously in the canine left ventricle with the use of noncontact multielectrode probes. The objective of the present study was to measure cavitary electrograms in the canine right atrium (RA) and describe the corresponding global activation sequences during normal and abnormal atrial rhythms. A 64-electrode custom probe was inserted into the RA of six dogs. Probe position and orientation were guided by fluoroscopy. Probe unipolar electrograms were acquired simultaneously during sinus rhythm, RA pacing, and ventricular pacing. Vagally mediated atrial fibrillation (AF) was induced in four dogs. Probe electrograms were acquired during AF induced at baseline and after intravenous infusion of ibutilide (0.075 mg/kg followed by 0.075 mg/kg infusion over 10 minutes). Isochrone maps were derived from noncontact probe electrograms and were displayed on a beat-by-beat basis during normal and paced rhythms. During AF, maps were displayed for 10 consecutive 100-ms windows. Isochrone maps of normal and paced beats revealed regions of early activation that were consistent with sites of wavefront initiation. During AF, multiple varying activation wavefronts were observed. At baseline, AF cycle length was 110 +/- 15 ms and the number of wavefronts was 1.72 +/- 0.25 per 100-ms window. After ibutilide, AF cycle increased to 182 +/- 36 ms (P = 0.018) and the number of wavefronts decreased to 0.82 +/- 0.14 per 100-ms window (P = 0.009). In conclusion, global electrophysiological imaging with a noncontact multielectrode probe delineates RA anatomy. Furthermore, images of AF activation depict multiple wandering wavefronts. Ibutilide reduces the number of these wavefronts and organizes AF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1998.tb01208.x | DOI Listing |
Sensors (Basel)
November 2022
College of Science, Kunming University of Science and Technology, Kunming 650504, China.
Traditional contact voltage measurement requires a direct electrical connection to the system, which is not easy to install and maintain. The voltage measurement based on the electric field coupling plate capacitance structure does not need to be in contact with the measured object or the ground, which can avoid the above problems. However, most of the existing flat-plate structure voltage measurement sensors are not only expensive to manufacture, but also bulky, and when the relative position between the wire under test and the sensor changes, it will bring great measurement errors, making it difficult to meet actual needs.
View Article and Find Full Text PDFRev Port Cardiol
June 2022
Serviço de Cardiologia, Hospital de Santa Marta, Centro Hospitalar Universitário Lisboa Central, Lisboa, Portugal.
Introduction: The outflow tract (OT) regions of the ventricles are a common location of origin for idiopathic ventricular arrhythmias (VA). Non-contact mapping (NCM) with a multi-electrode balloon catheter Ensite-Array enables three-dimensional reconstruction of the geometry of the cardiac chambers and accurate mapping of the propagation map, based on a single beat analysis, facilitating the ablation and contributing procedure success.
Objective: Assessment of the feasibility and long-term outcomes following NCM-guided OT VA ablation.
Front Physiol
July 2022
Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
Atrial fibrillation (AF) is the most common cardiac dysrhythmia and percutaneous catheter ablation is widely used to treat it. Panoramic mapping with multi-electrode catheters has been used to identify ablation targets in persistent AF but is limited by poor contact and inadequate coverage of the left atrial cavity. In this paper, we investigate the accuracy with which atrial endocardial surface potentials can be reconstructed from electrograms recorded with non-contact catheters.
View Article and Find Full Text PDFFront Physiol
May 2022
Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
Atrial fibrillation (AF) is the most prevalent cardiac dysrhythmia and percutaneous catheter ablation is widely used to treat it. Panoramic mapping with multi-electrode catheters can identify ablation targets in persistent AF, but is limited by poor contact and inadequate coverage. To investigate the accuracy of inverse mapping of endocardial surface potentials from electrograms sampled with noncontact basket catheters.
View Article and Find Full Text PDFCard Electrophysiol Clin
June 2020
Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, 9 Founders Pavilion, Philadelphia, PA 19104, USA. Electronic address:
High-density (HD) mapping presents opportunities to enhance delineation of atrial fibrillation (AF) substrate, improve efficiency of the mapping procedure without sacrificing safety, and afford new mechanistic insights regarding AF. Innovations in hardware, software algorithms, and development of novel multielectrode catheters have allowed HD mapping to be feasible and reliable. Patients to particularly benefit from this technology are those with paroxysmal AF in setting of preexisting atrial scar, persistent AF, and AF in the setting of complex congenital heart disease.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!