Rotational atherectomy for in-stent restenosis: acute and long-term results of the first 100 cases.

J Am Coll Cardiol

Cardiac Catheterization Laboratory of the Zena & Michael A. Wiener Cardiovascular Institute, Mount Sinai School of Medicine, New York, New York 10029-6574, USA.

Published: November 1998

AI Article Synopsis

Article Abstract

Objectives: This study evaluated the clinical safety and long-term results of rotational atherectomy (RA) followed by low-pressure balloon dilatation (percutaneous transluminal coronary angioplasty [PTCA]) for the treatment of in-stent restenosis (ISR).

Background: In-stent restenosis is associated with a high incidence of recurrence after interventional treatment. Because ISR is due to neointimal hyperplasia, rotational ablation may be a more effective treatment than PTCA.

Methods: Between November 1995 and November 1996, 100 consecutive patients with first-time ISR were treated by RA. Quantitative coronary angiography and intravascular ultrasound (IVUS) were used to analyze the acute procedural results. The incidence of repeat in-stent restenosis and target vessel revascularization (TVR) at follow-up was determined.

Results: Procedural success without any major in-hospital complications was achieved in 100% of cases. Slow flow was observed in 3% and creatine kinase-MB enzyme elevation >3x normal occurred in 2%. The mean burr-to-artery ratio was 0.68+/-0.18 and adjuvant balloon dilatation was performed at 4.2+/-2.1 atm. Minimum luminal diameter increased from 0.86+/-0.28 mm to 1.89< or =0.21 mm after RA and to 2.56+/-0.29 mm after adjunct PTCA. Quantitative IVUS analysis showed that 77% of the luminal gain occurred due to rotational ablation of the restenotic tissue and only 23% occurred after adjunct balloon dilation, and further stent expansion did not contribute to the luminal enlarge. ment. At a mean follow-up of 13+/-5 months, repeat in-stent restenosis occurred in 28% of patients with TVR of 26%. Univariate predictors of repeat restenosis were burr-to-artery ratio <0.6, ISR in <90 days of stenting, ostial lesion, stent for a restenotic lesion and diffuse type ISR.

Conclusions: Rotational atherectomy is a safe and feasible technique for treatment of ISR and is associated with a relatively low recurrent restenosis in comparison to historical controls of balloon angioplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0735-1097(98)00382-9DOI Listing

Publication Analysis

Top Keywords

in-stent restenosis
20
rotational atherectomy
8
balloon dilatation
8
rotational ablation
8
repeat in-stent
8
burr-to-artery ratio
8
restenosis
6
in-stent
5
rotational
4
atherectomy in-stent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!