A new simple cone-plate viscometer for hemorheology.

Clin Hemorheol Microcirc

Equipe Hémorhéologie-Angiohématologie, Laboratoire d'Energétique et de Mécanique Théorique et Appliquée, UMR CNRS 7563, Faculté de Médecine, Vandoeuvre-lès-Nancy, France.

Published: September 1998

The aim of this work was to evaluate a new automatic cone-plate viscometer (LBY-N6, PRECIL, Beijing, China) which was designed for clinical measurements of blood and plasma viscosities. Standard calibrating oils of viscosity varying from 1.85 to 20.5 mPas (conforming to ASTM Standard) were used to test the precision and reproducibility of the device. Then the viscometer was used to measure blood and plasma viscosities. The results were compared with those obtained with a conventional Couette viscometer and a capillary viscometer. The results showed that this new viscometer gave good values of viscosity for standard oils with relative errors lower than 10% at shear rates ranging from 20 to 200 s(-1). It also had a good reproducibility (standard deviations < 3% in most cases). Only the results at low shear rates (< 10 s(-1)) were less identical. As for blood, the relative difference between the results given by LBY-N6 and those obtained by Low Shear 30 was less than 10% at high shear rates. This difference decreased with shear rate and could be partly caused by viscoelastic and thixotropic properties of human blood. A small difference between the values of plasma viscosity obtained by LBY-N6 and the capillary viscometer AMTEC was also observed. In conclusion, this new viscometer can be used a routine tool to determine quickly plasma and blood viscosities in clinical practice at shear rates higher than 20 s(-1).

Download full-text PDF

Source

Publication Analysis

Top Keywords

shear rates
16
viscometer
8
cone-plate viscometer
8
blood plasma
8
plasma viscosities
8
capillary viscometer
8
low shear
8
shear
6
blood
5
simple cone-plate
4

Similar Publications

Objective: To introduce an innovative non-contact method for denudation process of cumulus-oocyte complexes (COCs) for intracytoplasmic sperm injection (ICSI).

Design: We designed and fabricated novel acousto-hydrodynamic tweezers (AHT) to perform contactless denudation and tested them in mouse model. Cumulus removal efficiency, preimplantation development and live birth were assessed and compared to conventional manual pipetting denudation.

View Article and Find Full Text PDF

Evaluation of rheological properties of guar gum-based fracturing fluids enhanced with hydroxyl group bearing thermodynamic hydrate inhibitors.

Int J Biol Macromol

December 2024

Department of Petroleum Engineering, School of Energy Technology, Pandit Deendayal Energy University, Gandhinagar, Gujarat 382426, India. Electronic address:

Naturally occurring gas clathrates are a significant methane resource-the primary component of natural gas, regarded as the cleanest hydrocarbon and a key feedstock for producing gray and blue hydrogen. Despite the global abundance of gas hydrate reserves, extraction via depressurization has yet to achieve commercially viable production rates. The primary limitation lies in the low permeability of hydrate-bearing sediments, where solid clathrates obstruct porous pathways, hindering dissociation and slowing gas recovery.

View Article and Find Full Text PDF

Hypothesis: The presence of hydrodynamic slip of water on smooth hydrophobic surfaces has been debated intensely over the last decades. In recent experiments, the stronger bounce of free-rising bubbles from smooth hydrophobic surfaces compared to smooth hydrophilic surfaces was interpreted as evidence for a significant water slip on smooth hydrophobic surfaces.

Experiments: To examine the possible water-slip effect, we conduct well-controlled experiments comparing the bouncing dynamics of millimeter-sized free-rising bubbles from smooth hydrophobic and hydrophilic surfaces.

View Article and Find Full Text PDF

It has long been speculated that the mechanical properties of the human oocyte can be an indicator for oocyte viability. Recent studies have demonstrated that embryo implantation rates, following Intra-Cytoplasmic Sperm Injection (ICSI) procedures, may be increased if the shear modulus value of the oocyte Zona Pellucida (ZP) is taken into consideration during embryo transfer. The shear modulus was determined by an iterative oocyte specific finite element (FE) analysis based on the clinical ICSI data.

View Article and Find Full Text PDF

Hypothesis: The porosity affects the rheological response of porous particle suspensions.

Experiments: Non-Brownian suspensions of porous particles immersed in a Newtonian Polyisobutene are investigated. Three different particles, with different porosity, pore structure and similar size, and non-porous irregular particles are used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!