A totally implantable centrifugal artificial heart has been developed. The plastic prototype, Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart, 2 week screening tests for antithrombogenicity, and 1 month system feasibility. Based on these results, a metallic prototype, Gyro PI 702, was subjected to in vivo left ventricular assist device (LVAD) studies. The pump system employed the Gyro PI 702, which has the same inner dimensions and the same characteristics as the Gyro PI 601, including an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI 702 is driven with the Vienna DC brushless motor actuator. For the in vivo LVAD study, the pump actuator package was implanted in the preperitoneal space in two calves, from the left ventricular apex to the descending aorta. Case 1 achieved greater than 9 month survival without any complications, at an average flow rate of 6.6 L/min with 10.2 W input power. Case 2 was killed early due to the excessive growth of the calf, which caused functional obstruction of the inlet port. There was no blood clot inside the pump. During these periods, neither case exhibited any physiologic abnormalities. The PI 702 pump gives excellent results as a long-term implantable LVAD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00002480-199809000-00064 | DOI Listing |
Acta Bioeng Biomech
June 2024
1Department of Biomedical Engineering, Hefei University of Technology, Hefei, People's Republic of China.
: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.
View Article and Find Full Text PDFEur J Cardiothorac Surg
January 2025
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany. DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
Objectives: This fourth report aimed to provide insights into patient characteristics, outcomes, and standardized outcome ratios of patients implanted with durable Mechanical Circulatory Support across participating centers in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry.
Methods: All registered patients receiving durable mechanical circulatory support up to August 2024 were included. Expected number of events were predicted using penalized logistic regression.
Eur Heart J Cardiovasc Imaging
January 2025
Heart Institute. Department of Cardiology. Cardiovascular Imaging Unit. Hospital Universitari Germans Trias i Pujol, Barcelona, Spain.
Aims: How the underlying etiology and pathophysiology of left ventricular (LV) hypertrophy affects LA remodeling and function remains unexplored. The present study aims to investigate the influence of various hypertrophic phenotypes on LA remodeling and function.
Methods And Results: Patients with LV hypertrophy who underwent cardiac magnetic resonance (CMR) were compared to a control group.
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
J Craniofac Surg
January 2025
School of Medical Imaging, Hangzhou Medical College, Hangzhou, China.
Thalamic hemorrhage is a type of intracerebral hemorrhage with high disability and mortality rates. Because of its deep bleeding location, irregular shape of the hematoma, and compression of the third ventricle, it is not suitable for craniotomy. This paper reports a case of a 63-year-old male patient who sought medical attention for left-sided basal ganglia and thalamus hemorrhage that broke into the ventricles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!