Background And Purpose: We describe four cases of aneurysmal rupture during embolization with Guglielmi electrodetachable coils (GDCs) in an attempt to identify those aneurysms whose rupture during embolization represents a life-threatening risk; our emphasis is on emergency management, in particular, ventriculostomy.
Methods: Medical records were reviewed retrospectively for 91 aneurysms treated with GDCs 0 to 21 days after subarachnoid hemorrhage. Rupture was ascertained by the presence of extravascular effusion of contrast medium.
Results: Of the perforated aneurysms, two involved the anterior communicating artery, one the posterior inferior communicating artery, and one the basilar artery. Only two patients, whose aneurysms were located in the posterior fossa, had major complications (arterial hyperpressure, mydriasis, angiographically documented circulatory arrest or slowing). One of these patients died and the other improved after emergency ventriculostomy.
Conclusion: Aneurysmal perforation during embolization may be accompanied by severe intracranial hypertension, which causes either a decrease or arrest of cerebral perfusion, the duration of which determines clinical outcome. Emergency ventriculostomy (which should be performed in the angiographic suite) is an effective means to reduce intracranial pressure. Recognition of aneurysms associated with a high risk of mortality by rupture in the course of embolization (recently ruptured small aneurysms, posterior fossa aneurysms, associated ventricular dilatation, massive cisternal hemorrhage) and use of proper logistics should ensure the effective management of this devastating complication.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8337490 | PMC |
Langenbecks Arch Surg
January 2025
Department of Trauma Surgery, University Hospital Zurich, Rämistrasse 100, CH - 8091, Zurich, Switzerland.
Introduction: Blunt traumatic aortic injury (TAI) is a critical condition and a leading cause of mortality in trauma patients, often resulting from high-speed accidents. Thoracic endovascular aortic repair (TEVAR) has developed into the preferred therapeutic approach due to its minimally invasive nature and promising outcomes. This study evaluates the safety and efficacy of TEVAR for managing TAI over a 10-year period at a Level-1 trauma center.
View Article and Find Full Text PDFWe present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.
View Article and Find Full Text PDFJ Coll Physicians Surg Pak
January 2025
Department of General and Laparoscopic Surgery, Sheikh Khalifa Bin Zayed Al-Nahyan Hospital Muzaffarabad, Azad Jammu and Kashmir, Pakistan.
Objective: To determine the importance of the Glasgow Coma scale (GCS), ASA physical status classification system, and P-POSSUM score in predicting mortality among patients undergoing emergency laparotomies.
Study Design: An analytical study. Place and Duration of the Study: Department of General Surgery, Sheikh Khalifa Bin Zayed Al-Nahyan Hospital Muzaffarabad, Pakistan, from October 2020 to January 2022.
BMC Pulm Med
January 2025
Division of Pulmonology and Critical Care Medicine, Department of Internal Medicine, College of Medicine, Chungnam National University, Daejeon, 301-721, Republic of Korea.
Background: Behçet's disease (BD) is a multisystem inflammatory disorder that can affect various organs, including the lungs. Pulmonary manifestations are rare and typically present as pulmonary artery aneurysms.
Case Presentation: We report the case of a 56-year-old East Asian male with a 27-year history of BD, who had no respiratory symptoms, such as hemoptysis, cough, or fever.
Int J Cardiovasc Imaging
January 2025
Department of Cardiovascular Surgery, Jichi Medical University Saitama Medical Center, 1- 847 Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan.
This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!