Statement Of Problem: Earlier studies on orthodontic brackets have shown a loss of bond strength after a sonic toothbrush was used.
Purpose: This in vitro study evaluated the difference in bond strength of single complete veneer crowns after being subjected to the equivalent of 2 years of brushing with sonic and counterrotational toothbrushes.
Material And Methods: Complete gold crowns were fabricated with a conventional indirect technique for 30 extracted, intact, prepared human premolar teeth. Castings were then luted to the teeth with glass ionomer cement. Teeth were randomly divided into 3 groups of 10 teeth each, 1 group to be brushed with Sonicare sonic toothbrush, 1 group to be brushed with Interplak counterrotational mechanical toothbrush, and 1 group as the control. Groups 1 and 2 were then brushed for the equivalent of 2 years per tooth. A uniform force of 50 g for the sonic toothbrush and 120 g for the counterrotational toothbrush was used. Control specimens were not brushed. Brush heads and sample teeth in contact with the toothbrush were kept moist at all times. Tensile dislodgment force was determined with an Instron universal testing machine.
Results: The castings brushed with a sonic toothbrush required a mean of 43.22 kg (+/- 11.16) force to remove the crowns from the teeth, whereas the counterrotational group required a mean of 42.87 kg (+/- 10.42) and the control group a mean of 42.12 kg (+/- 6.61). Analysis of variance on the force data indicated no differences among the 3 groups in the force needed to remove the castings (F[2,24] = 0.031, P = .97).
Conclusion: This in vitro study demonstrated no significant differences between groups in the amount of tensile dislodgment force required to remove cemented full veneer crowns from prepared teeth after brushing for the equivalent of 2 years time with a sonic toothbrush or a counterrotational toothbrush.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0022-3913(98)70007-1 | DOI Listing |
Clin Cosmet Investig Dent
October 2024
School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Front Public Health
October 2024
Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing, China.
Dent J (Basel)
July 2024
Department of Neurosciences-Dentistry Section, Università degli Studi di Padova, 35122 Padova, Italy.
Background: Oral hygiene is crucial for the success of orthodontic therapy involving temporary anchoring devices like miniscrews. Plaque buildup, exacerbated by orthodontic appliances, causes inflammation that can undermine treatment outcomes. Individualized prevention plans based on patient risk factors are essential.
View Article and Find Full Text PDFJ Prosthet Dent
September 2024
Private Practice, Istanbul, Turkey.
Statement Of Problem: Early tightening torque at the implant-healing abutment interface is a recognized concern in implant treatment. However, little is known regarding the effects of toothbrushing methods on the interface established between the implant and healing abutments of different heights.
Purpose: The purpose of this in vitro study was to evaluate the effect of different toothbrushing methods on tightening torque for healing abutments of different heights.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!