The aim of this work was to study the possibilities and limits of the vascular microanastomoses with VCS microclips. VCS Microclips are a new mechanical anastomotic device, allowing a single operator to perform anastomoses without microsutures. The two arcuate limbs of the titanium microclips do not penetrate the vascular intima. The microclip anastomosis technique is based on symmetric eversion of the vessel walls, facilitated by everting forceps. We studied the medium and small Autosuture VCS microclips on different vessels ranging from 0.3 to 2 millimeters in diameter: aorta, carotid artery, femoral artery and femoral vein. Thirty nine end-to-end or end-to-side anastomoses were performed on Wistar rats. These anastomoses were performed by a single operator without the use of sutures. Patency was studied by the "empty and refill" test immediately and at two months. Histologic analysis of the anastomosis was performed at two months (hematein-eosin and orcein stains on longitudinal sections). Four out of thirty nine anastomoses were occluded during the 15 minutes following clamp release. Failure was always due to a technical error and occurred during the first trials. The thirty five other anastomoses were patent immediately and at two months post-operatively, except for the by-pass which was not viable. These anastomoses were still patent 30 minutes post-operatively. Light microscopy analysis confirmed that the microclip extremities did not penetrate the lumen, although the internal media was usually very thin at the level of the microclip jaws, especially for the smallest vessels. For vessels larger than 1 mm in diameter, the microclip extremities were usually outside the internal elastic lamina. No anastomotic aneurysm was found. Vascular healing was comparable with microsutures at 2 months. Microvascular anastomoses performed with microclips have numerous advantages, compared to usual microsutures: they are two to three times quicker, they can be performed step by step without turning the clamp and they can be performed with the right or left hand. There is theoretically no thrombogenic risk. The drawbacks are the need for complementary training and the cost of microclips which is five to six times that of sutures. End-to-side anastomoses of small vessels are more difficult than end-to-end anastomoses. The recipient vessels must be larger than 1.5 mm in diameter, otherwise the anastomosis may become stenosed. Microclips are especially useful to save time, i.e. for multiple anastomoses and for anastomoses of vessels larger than 1 millimeter in diameter. Some modifications of the material could allow vascular or hollow organ anastomoses with endoscopic assistance.
Download full-text PDF |
Source |
---|
Neurol Res
December 2004
Department of Surgery, Cook County Hospital, Chicago, IL, USA.
Introduction: Alexis Carrel pioneered the full-thickness triangulated vascular repair technique, which led to a Nobel Prize in 1912. However, microvascular anastomotic techniques that do not violate the intima, such as the VCS microclip repair and partial-thickness suturing, limit trauma to the intima, thus minimizing the potential for thrombosis. Our study compares such techniques with the standard full thickness-anastomotic repair.
View Article and Find Full Text PDFEur Urol
July 2001
Department of Urology, Ospedale Nuovo, Via dei Lotti 40, I-36061 Bassano, Italy.
Introduction: As urologists head into the new millennium, it has become clear that laparoscopy will play a significant role in successful urologic practice. Issues that are addressed in this article include: (1) What are the new limits? (2) Technological advances. (3) Adequate training.
View Article and Find Full Text PDFAnn Chir Plast Esthet
February 1998
Laboratoire de Microchirurgie de Paris VII (Saint-Louis, Lariboisière.
The aim of this work was to study the possibilities and limits of the vascular microanastomoses with VCS microclips. VCS Microclips are a new mechanical anastomotic device, allowing a single operator to perform anastomoses without microsutures. The two arcuate limbs of the titanium microclips do not penetrate the vascular intima.
View Article and Find Full Text PDFAnn Thorac Surg
June 1997
Department of Plastic and Reconstructive Surgery, Catholic University Leuven, Belgium.
Background: Despite the high percentages of experimental and clinical patency rates achieved using so-called mechanical anastomotic devices (Unilink; 3M, St. Paul, MN; vascular staples) they remain little known and occasionally used.
Methods: The VCS Auto Suture microstapler technique for microvascular anastomosis was tested experimentally and compared with the conventional "gold standard" 10/0 end-to-end microvascular technique.