The influence of surface quality, in particular surface topography and implant material, was evaluated by inserting titanium- and hydroxylapatite plasma-sprayed coated implants into the maxilla of 10 goats. Three types of plasma-spray coatings were applied to tapered, screw shaped implants; titanium plasma-spray coating (TPS), titanium plasma-spray coating with additional acid passivation (TPSA) and a bilayered coating (TPS/HA) consisting of titanium plasma-spray coating (TPS) and a hydroxylapatite part (HA). In addition, as-machined implants (TiM) were used as control. A total of 40 implants were inserted according a balanced split plot design. At the end of a 3-month healing period, it appeared that 5 implants (2 TPS, 1 TPSA, 1 TPS/HA and 1 TiM) were lost. Histological examination revealed a stronger bone response to TPS/HA coated implants. Even the TPS/HA coated implants induced bone formation on the part of the implant inserted into the sinus. No signs of delamination of the TPS coatings were visible. The HA part of the dual coating showed signs of degradation. Histomorphometrical analysis confirmed these findings. A significant difference in bone contact (P < 0.05) was measured between the TPS/HA coated implants and the other types of implants. Linear regression (r = 0.27) showed no correlation between the inscrew values at the base line and the bone contact measurements 3 months after healing. On the basis of these results, we can conclude that the chemical composition of the HA coating has a positive influence on the bone reaction. The influence of roughness is less evident.

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0501.1998.090407.xDOI Listing

Publication Analysis

Top Keywords

coated implants
16
titanium plasma-spray
12
plasma-spray coating
12
tps/ha coated
12
implants
10
coating tps
8
bone contact
8
bone
6
coating
6
tps/ha
5

Similar Publications

Introduction: Chronic inflammation leading to implant failure present major challenges in orthopedics, dentistry, and reconstructive surgery. Titanium alloys, while widely used, often provoke inflammatory complications. Zinc-doped calcium phosphate (CaP) coatings offer potential to enhance implant integration by improving corrosion resistance, bioactivity, and immunocompatibility.

View Article and Find Full Text PDF

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Optical neural implants allow neuroscientists to access deep brain regions, enabling to decipher complex patterns of neural activity. In this field, the use of optical fibers is rapidly increasing, and the ability to generate high-quality metal patterns on their non-planar surface would further extend their application. Here, we propose to use alternating metal shielding and dielectric confinement to engineer the mode-division properties of tapered optical fiber neural implants.

View Article and Find Full Text PDF

In the present in vitro study, we evaluated the adhesion of an injectable platelet-rich fibrin (i-PRF) to laser-textured zirconia surfaces and their resultant friction behavior against bone tissue. Three types of zirconia surfaces were compared regarding the i-PRF coating effects: 1) grit blasted with 250-μm spherical alumina particles and acid etched with 20% hydrofluoric acid (ZLA), 2) laser textured with a random (RD) surface pattern, or 3) laser textured with a designed pattern based on 16 lines and 8 passages (L16N8). The coefficient of friction (COF) of the specimens was assessed on a reciprocating sliding pin-on-plate tribometer at 1-N normal load, 1 Hz, and a 2-mm stroke length.

View Article and Find Full Text PDF

CCN5 suppresses injury-induced vascular restenosis by inhibiting smooth muscle cell proliferation and facilitating endothelial repair via thymosin β4 and Cd9 pathway.

Eur Heart J

January 2025

State Key Laboratory of Cardiovascular Diseases and Medical Innovation Center, Shanghai Heart Failure Research Center, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120, China.

Background And Aims: Members of the CCN matricellular protein family are crucial in various biological processes. This study aimed to characterize vascular cell-specific effects of CCN5 on neointimal formation and its role in preventing in-stent restenosis (ISR) after percutaneous coronary intervention (PCI).

Methods: Stent-implanted porcine coronary artery RNA-seq and mouse injury-induced femoral artery neointima single-cell RNA sequencing were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!