A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry. | LitMetric

Microfabrication technology offers the opportunity to construct microfluidic modules which are designed to perform specific, dedicated functions. Here we report the construction of a microfabricated device for the generation and delivery by electroosmotic pumping of solvent gradients at nanoliter per minute flow rates. The device consists of three solvent reservoirs and channels which were etched in glass. Solvent gradients and solvent flows were generated by computer controlled differential electroosmotic pumping of aqueous and organic phase, respectively, from the solvent reservoirs. The device was integrated into an analytical system consisting of the solvent gradient delivery module, a reverse phase microcolumn and an electrospray ionization ion trap mass spectrometer (MS). The system was used for the analysis at high sensitivity of peptides and peptide mixtures generated by proteolytic digestion of proteins. We have measured an absolute limit of detection as low as 1 fmol and a concentration limit of detection at the 100 amol/microL level. The system was also successfully used for the identification of proteins separated by 1D and 2D gel electrophoresis. This was achieved by gradient frontal analysis of the peptide mixture generated by proteolysis of the respective proteins, and the automated generation and interpretation of collision-induced dissociation spectra.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac980502jDOI Listing

Publication Analysis

Top Keywords

solvent gradient
8
gradient delivery
8
microfabricated device
8
electrospray ionization
8
electroosmotic pumping
8
solvent gradients
8
solvent reservoirs
8
limit detection
8
solvent
6
nanoflow solvent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!