Some electrocardiographic appearances in cardiac pacing may suggest pacemaker dysfunction but in fact the unit may be functioning normally or have a minor fault which is easy to correct by reprogramming. A pacing rate different to that programmed may be due to the rate-response hysteresis or rate smoothing functions. Irregular pacing is often due to phenomena of inappropriate sensing. A pacemaker in the bipolar AAI mode may seem to have no output if the spike is not visible: function in AAI mode should not be interpreted as pacing catheter displacement. The practician may wrongly interpret faulty ventricular sensing in patients with AAI pacemakers and atrial fibrillation when irregular pacing is observed or when ventricular extrasystoles do not inhibit the pacemaker. In dual chamber pacing, the blanking period may result in inadequate ventricular stimulation. The phenomenon of crossed detection or cross-talk is a cause of inappropriate inhibition. Applications of the magnet blocks the sensing function: the magnet pacemaker rate is an indicator of pacemaker end of life. In fact, the magnet induces different behaviours depending on the model of pacemaker which makes it essential to know the special characteristics of each pacemaker. The application of the magnet may trigger arrhythmias or no output of pacemakers at the end of life. The A-V interval may vary with respect to its response to the heart rate, when there is a hysteresis function of the A-V interval, sensing in the "safety" gap or when anti-atrial trachycardia algorithms are activated. The acceleration of a dual-chamber pacemaker may be related to electronic reentrant tachycardia or to an atrial tachycardia: a fault or delayed activation of various anti-arrhythmic algorithms may also cause difficulties in the interpretation of the electrocardiogram.
Download full-text PDF |
Source |
---|
Expert Rev Med Devices
January 2025
Cardiology Unit, "Card. G. Panico" Hospital, Tricase (Le), Italy.
Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.
View Article and Find Full Text PDFJ Cardiovasc Surg (Torino)
December 2024
Department of Cardiovascular and Thoracic Surgery, Dijon University Hospital, Dijon, France.
Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.
Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.
Background: Prescription for inappropriate drugs can be dangerous to very old people, due to the increased risk of adverse drug reactions.
Case Report: We report the consequences of inappropriate prescriptions in a 99-year-old woman. She had a clinical history of vascular dementia, diabetes, hypothyroidism, heart failure, osteoarthritis, chronic renal failure, and hypoacusia, and was admitted to our attention for asthenia and loss of appetite.
Int J Med Sci
January 2025
Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, MALAYSIA.
The finger photoplethysmography fitness index (PPGF), a marker of peripheral vascular function, has been linked to heart rate (HR) variability. However, the influence of acute HR changes on resting PPGF, a purported indicator of local blood flow, remains unclear. This study aimed to determine the influence of acute HR changes on resting PPGF.
View Article and Find Full Text PDFKardiochir Torakochirurgia Pol
December 2024
Department of Cardiovascular Surgery, Faculty of Medicine, Hacettepe University, Ankara, Turkey.
Introduction: Patients who need tricuspid valve replacement (TVR) surgery often have permanent transvalvular pacemaker (PM) leads, which pose an important challenge in lead management.
Aim: The objective of this study was to evaluate the results of paravalvular positioning of a permanent pacemaker lead during TVR surgery.
Material And Methods: Between 2014 and 2024, a total of 15 patients who had previously had a transvenous pacemaker system underwent TVR.