Purpose: To present a large series of choroidal hemangiomas treated with proton beam irradiation and to describe the treatment outcomes.
Methods: We treated 54 eyes of 53 patients with choroidal hemangioma. The lesions consisted of 48 circumscribed hemangiomas and six diffuse hemangiomas in patients with Sturge-Weber syndrome. The total applied dose was 27.3 Gy in four eyes, 22.7 Gy in three eyes, and 16.4 Gy to 18.2 Gy in 47 eyes.
Results: The retina reattached within six months after treatment in all 54 eyes and no recurrence of the secondary retinal detachment occurred within the follow-up period of 6 months to 9 years. Tumors treated with the higher doses regressed faster than tumors treated with the lower doses, but radiation-induced complications of the optic nerve appeared in all four eyes treated with a total dose of 27.3 Gy. Of 31 eyes treated with 16.4 to 18.2 Gy and followed for more than 1 year, 22 had an improvement in their visual acuity, and nine retained the same visual acuity. At the last follow-up examination, the best-corrected visual acuity was 20/20 or better in nine eyes, 20/40 to 20/25 in 13 eyes, 20/100 to 20/50 in six eyes, and 20/200 or less in three eyes.
Conclusions: Proton beam irradiation of choroidal hemangiomas appears to be a valid therapeutic alternative. A total proton dose ranging from 16.4 to 18.2 Gy applied in four daily fractions seems adequate to ensure local control of both tumor and secondary retinal detachment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9394(98)00150-0 | DOI Listing |
Int J Radiat Oncol Biol Phys
January 2025
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA. Electronic address:
Purpose: Proton FLASH has been investigated using cyclotron and synchrocyclotron beamlines but not synchrotron beamlines. We evaluated the impact of dose rate (ultra-high [UHDR] vs. conventional [CONV]) and beam configuration (shoot-through [ST] vs.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Cox 308, Boston, MA 02114, USA.
The management of periocular skin malignancies presents a unique challenge. Proton beam therapy, due to its sharp dose fall-off, allows for the delivery of a tumoricidal dose to the tumor while sparing adjacent normal tissues. Thirteen patients with a median age of 76.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Radiotherapy and Radiosurgery Department, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089 Milan, Italy.
Background: Radiotherapy for thymoma is delivered post-operatively in selected cases. Given the particular location of the thymic bed and the excellent prognosis, late cardiac toxicities may be an issue. The purpose of this retrospective dosimetric study is to investigate whether intensity-modulated proton beam therapy (IMPT) compared to photon therapy could better spare cardiac substructures, given prespecified dose constraints.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Ophthalmology, University of Lübeck, University Medical Center Schleswig-Holstein, Campus Lübeck, 23562 Lübeck, Germany.
: Accurate target definition, treatment planning and delivery increases local tumor control for radiotherapy by minimizing collateral damage. To achieve this goal for uveal melanoma (UM), tantalum fiducial markers (TFMs) were previously introduced in proton and photon beam radiotherapy. However, TFMs cause pronounced scattering effects in imaging that make the delineation of small tumors difficult.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Intense Laser Irradiation Laboratory, National Institute of Optics, National Research Council of Italy, 56124 Pisa, Italy.
The use of very high energy electron (VHEE) beams, with energies between 50 and 400 MeV, has drawn considerable interest in radiotherapy due to their deep tissue penetration, sharp beam edges, and low sensitivity to tissue density. VHEE beams can be precisely steered with magnetic components, positioning VHEE therapy as a cost-effective option between photon and proton therapies. However, the clinical implementation of VHEE therapy (VHEET) requires advances in several areas: developing compact, stable, and efficient accelerators; creating sophisticated treatment planning software; and establishing clinically validated protocols.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!