This document is intended to assist towards the WHO objective that external quality assessment (EQA) schemes be established at national and/or regional levels world-wide. Quality assurance is defined as all steps taken by the director of a laboratory to ensure reliability of laboratory results and to increase accuracy, reproducibility and between-laboratory comparability. This includes the use of internal quality control procedures and participation in external quality assessment. Internal quality control provides the means for evaluation of analytic test results at the time of testing in order to decide whether they are reliable enough to be released to the requesting clinicians. EQA, on the other hand, refers to a system of retrospective and objective comparison of results from different laboratories by means of proficiency testing (PT) organised by an external agency. The main purpose is to establish between-laboratory and between-method (including between-instrument) comparability, and agreement with a reference standard where one exists. Internal quality control and EQA complement each other and must never be considered as alternatives.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0925-5710(98)00032-2DOI Listing

Publication Analysis

Top Keywords

external quality
12
quality assessment
12
internal quality
12
quality control
12
proficiency testing
8
quality
7
guidelines organisation
4
organisation management
4
external
4
management external
4

Similar Publications

Following anterior cruciate ligament (ACL) injury, quadriceps muscle atrophy persists despite rehabilitation, leading to loss of lower limb strength, osteoarthritis, poor knee joint health and reduced quality of life. However, the molecular mechanisms responsible for these deficits in hypertrophic adaptations within the quadriceps muscle following ACL injury and reconstruction are poorly understood. While resistance exercise training stimulates skeletal muscle hypertrophy, attenuation of these hypertrophic pathways can hinder rehabilitation following ACL injury and reconstruction, and ultimately lead to skeletal muscle atrophy that persists beyond ACL reconstruction, similar to disuse atrophy.

View Article and Find Full Text PDF

Purpose: This study evaluates the effectiveness of the inverted internal limiting membrane (ILM) flap technique during vitrectomy for treating macular hole-induced retinal detachment (MHRD) in high myopia patients, a challenging complication for vitreoretinal surgeons due to its treatment complexity.

Methods: We conducted a prospective study analyzing 92 eyes diagnosed with MHRD, all undergoing vitrectomy using the inverted ILM flap technique between February 2022 and September 2024. Successful surgery was defined as achieving retinal reattachment, macular hole closure, and improvement in visual acuity by the 12-month postoperative follow-up.

View Article and Find Full Text PDF

Purpose: The aim was to assess the long-term functional outcome and quality of life after staged surgical treatment of complex Lisfranc and Chopart injuries in a patient cohort, and to perform a systematic review of the literature.

Methods: A retrospective cohort of all trauma patients with complex Lisfranc and/or Chopart injuries treated at our level 1 trauma center between July 1, 2010, and July 1, 2020 with ≥ 3 years follow-up was analyzed in terms of management, complications, and patient-reported outcomes (American Orthopaedic Foot & Ankle Society midfoot score, AOFAS and Foot Function Index, FFI). A systematic review of the literature (according to PRISMA 2020 guidelines) was performed of studies published between January 2000 to April 2024.

View Article and Find Full Text PDF

Mid-Infrared High-Power InGaAsSb/AlGaInAsSb Multiple-Quantum-Well Laser Diodes Around 2.9 μm.

Nanomaterials (Basel)

January 2025

Key Laboratory of Optoelectronic Materials and Devices, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.

Antimonide laser diodes, with their high performance above room temperature, exhibit significant potential for widespread applications in the mid-infrared spectral region. However, the laser's performance significantly degrades as the emission wavelength increases, primarily due to severe quantum-well hole leakage and significant non-radiative recombination. In this paper, we put up an active region with a high valence band offset and excellent crystalline quality with high luminescence to improve the laser's performance.

View Article and Find Full Text PDF

Background: Postoperative ileus (POI) is a common postoperative clinical complication that significantly affects postoperative rehabilitation and quality of life in patients and can even produce secondary complications, leading to serious consequences. External treatment using Shenhuang Plaster (SHP) (Shenque acupoint administration) has definite effects and unique advantages in the prevention and treatment of POI, but its mechanism is not completely clear. In this study, we investigated the therapeutic mechanism behind the effect of Shenhuang Plaster applied to the Shenque acupoint on gastrointestinal motility in POI mice based on metabolomics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!