The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/028418517601700402 | DOI Listing |
Eur J Neurol
February 2025
IRCCS Istituto delle Scienze Neurologiche di Bologna, Department of Neurology and Stroke Center, Maggiore Hospital, Bologna, Italy.
Background: To investigate the relevance of hyperperfusion on computerised perfusion imaging (CTP) in the emergency setting in people with non-convulsive status epilepticus (NCSE) and previous stroke, to derive relevant aspects on the epileptogenic focus and the network recruited for NCSE propagation.
Methods: We enrolled consecutive adult patients with acute-onset NCSE and a previous stroke at a single institution undergoing CTP and EEG during symptoms. All patients underwent standard imaging including CT, CTP, CT angiograms and standard EEG within 30 min from hospital arrival.
Bioelectromagnetics
January 2025
Micropropulsion and Nanotechnology Laboratory, School of Engineering and Applied Science, George Washington University, Washington, DC, USA.
Cancer remains a formidable global health challenge, necessitating the development of innovative diagnostic techniques capable of early detection and differentiation of tumor/cancerous cells from their healthy counterparts. This review focuses on the confluence of advanced computational algorithms with noninvasive, label-free impedance-based biophysical methodologies-techniques that assess biological processes directly without the need for external markers or dyes. This review elucidates a diverse array of state-of-the-art impedance-based technologies, illuminating distinct electrical signatures inherent to cancer vs healthy tissues.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Chemistry, Faculty of Science, Hokkaido University, Sapporo, Hokkaido, Japan.
Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.
Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.
NMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.
View Article and Find Full Text PDFAbdom Radiol (NY)
January 2025
Mayo Clinic, Rochester, MN, USA.
Purpose: To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm).
Methods: Patients undergoing clinical dual-energy EID-CT for known or suspected stone disease underwent same-day research PCD-CT. Patients with greater than 10 stones and no visible stones under 3 mm were excluded.