The oxygen flow rate delivered by liquid oxygen canisters may be less than intended, owing to inaccuracies of the set flow rates and/or as a result of the outflow resistance caused by the humidifier, oxygen tubing, delivery or conserving device. The aim of this study was to investigate the accuracy of oxygen delivery by liquid oxygen canisters at different flow rates and levels of outflow resistance. Four stationary and 18 portable liquid oxygen canisters from three manufacturers were tested. All flows were measured using a Timemeter RT 200 Calibration Analyser. An adjustable obstruction was used to calculate the effect of the outflow resistance on the delivered flow rate. The measured and set flow rates of both stationary and portable canisters were strongly correlated. Expressed as a percentage of the set flow rate, the measured flow rate of the canisters varied from 36-128%, with the lowest values at flow rates <1 L x min(-1). Sixty-two (26%) of the measured flow rates differed > or =10% from the set flow rate. A difference of 0.5-1.0 L x min(-1) occurred in 16 (7%) of the measurements, but only at set flow rates >2 L x min(-1). Irrespective of the set flow rate, the measured flow rate was hardly affected by the outflow resistance. We conclude that the accuracy of oxygen delivery by liquid oxygen canisters depends on the inaccuracy of the set flow rates rather than on the outflow resistance, even at high flow rates. Although the differences between the measured and set flow rates were mostly small, they may have clinical significance, particularly in patients with chronic obstructive pulmonary disease. To prevent inaccuracy, monthly checks of the canisters by the oxygen provider at the patient's home are more important than yearly maintenance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1183/09031936.98.12010204 | DOI Listing |
Pulmonology
December 2025
Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo dei tintori, Monza, Italy.
Background: Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP.
View Article and Find Full Text PDFJ Exp Biol
January 2025
Centre de Recherches sur la Cognition Animale, CNRS, Université Paul Sabatier, Toulouse 31062 cedex 09, France.
Solitary foraging insects like desert ants rely heavily on vision for navigation. While ants can learn visual scenes, it is unclear what cues they use to decide if a scene is worth exploring at the first place. To investigate this, we recorded the motor behavior of Cataglyphis velox ants navigating in a virtual reality set-up (VR) and measured their lateral oscillations in response to various unfamiliar visual scenes under both closed-loop and open-loop conditions.
View Article and Find Full Text PDFFront Sports Act Living
January 2025
Department of Physical Therapy, Faculty of Rehabilitation Sciences, Nishi Kyushu University, Kanzaki-cho, Japan.
Introduction: Inter-set rest intervals are essential to reduce muscle fatigue and increase the total amount of volume of resistance training. Static stretching and walking may increase muscle blood flow and promote recovery during inter-set rest intervals. Therefore, the purpose of this study was to investigate the effects of 20 seconds of static stretching and walking during inter-set rest intervals of leg extension exercises on the number of repetitions to exhaustion, total amount of volume, and flexibility of the quadriceps (joint range of motion and muscle hardness) in untrained healthy males.
View Article and Find Full Text PDFCureus
December 2024
University of Florida Health Congenital Heart Center, University of Florida College of Medicine, Gainesville, USA.
Anomalous aortic origin of a coronary artery (AAOCA) comprises a set of rare congenital abnormalities in the origin or path of the coronary arteries with highly variable clinical implications. This is a pilot feasibility study where we investigated the influence of the anomalous coronary artery inlet architecture on coronary perfusion using coronary blood flow computational simulations to help predict the risk for coronary ischemia in patients with anomalous aortic origin of the right coronary artery (AAORCA) with these types of anomalous coronary artery inlet architectures. We developed a protocol for generating 3D models of patient coronary artery anatomies from an IRB-approved dataset of cardiac CT images of patients with AAORCA at our institution.
View Article and Find Full Text PDFPLoS One
January 2025
School of Life Course and Population Sciences, King's College London, London, United Kingdom.
Introduction: High-Flow Nasal Therapy (HFNT) is an innovative non-invasive form of respiratory support. Compared to standard oxygen therapy (SOT), there is an equipoise regarding the effect of HFNT on patient-centred outcomes among those at high risk of developing postoperative pulmonary complications after undergoing cardiac surgery. The NOTACS trial aims to determine the clinical and cost-effectiveness of HFNT compared to SOT within 90 days of surgery in the United Kingdom, Australia, and New Zealand.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!