Accuracy of oxygen delivery by liquid oxygen canisters.

Eur Respir J

Centre for Home Mechanical Ventilation, Division of Internal Medicine and Dermatology, University Hospital Utrecht, The Netherlands.

Published: July 1998

The oxygen flow rate delivered by liquid oxygen canisters may be less than intended, owing to inaccuracies of the set flow rates and/or as a result of the outflow resistance caused by the humidifier, oxygen tubing, delivery or conserving device. The aim of this study was to investigate the accuracy of oxygen delivery by liquid oxygen canisters at different flow rates and levels of outflow resistance. Four stationary and 18 portable liquid oxygen canisters from three manufacturers were tested. All flows were measured using a Timemeter RT 200 Calibration Analyser. An adjustable obstruction was used to calculate the effect of the outflow resistance on the delivered flow rate. The measured and set flow rates of both stationary and portable canisters were strongly correlated. Expressed as a percentage of the set flow rate, the measured flow rate of the canisters varied from 36-128%, with the lowest values at flow rates <1 L x min(-1). Sixty-two (26%) of the measured flow rates differed > or =10% from the set flow rate. A difference of 0.5-1.0 L x min(-1) occurred in 16 (7%) of the measurements, but only at set flow rates >2 L x min(-1). Irrespective of the set flow rate, the measured flow rate was hardly affected by the outflow resistance. We conclude that the accuracy of oxygen delivery by liquid oxygen canisters depends on the inaccuracy of the set flow rates rather than on the outflow resistance, even at high flow rates. Although the differences between the measured and set flow rates were mostly small, they may have clinical significance, particularly in patients with chronic obstructive pulmonary disease. To prevent inaccuracy, monthly checks of the canisters by the oxygen provider at the patient's home are more important than yearly maintenance.

Download full-text PDF

Source
http://dx.doi.org/10.1183/09031936.98.12010204DOI Listing

Publication Analysis

Top Keywords

set flow
32
flow rates
32
flow rate
28
liquid oxygen
20
oxygen canisters
20
outflow resistance
20
flow
15
accuracy oxygen
12
oxygen delivery
12
delivery liquid
12

Similar Publications

Not too much, not too little. Titrating flow rate to minimise inspiratory effort during helmet CPAP: A bench study.

Pulmonology

December 2025

Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo dei tintori, Monza, Italy.

Background: Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP.

View Article and Find Full Text PDF

Solitary foraging insects like desert ants rely heavily on vision for navigation. While ants can learn visual scenes, it is unclear what cues they use to decide if a scene is worth exploring at the first place. To investigate this, we recorded the motor behavior of Cataglyphis velox ants navigating in a virtual reality set-up (VR) and measured their lateral oscillations in response to various unfamiliar visual scenes under both closed-loop and open-loop conditions.

View Article and Find Full Text PDF

Introduction: Inter-set rest intervals are essential to reduce muscle fatigue and increase the total amount of volume of resistance training. Static stretching and walking may increase muscle blood flow and promote recovery during inter-set rest intervals. Therefore, the purpose of this study was to investigate the effects of 20 seconds of static stretching and walking during inter-set rest intervals of leg extension exercises on the number of repetitions to exhaustion, total amount of volume, and flexibility of the quadriceps (joint range of motion and muscle hardness) in untrained healthy males.

View Article and Find Full Text PDF

Anomalous aortic origin of a coronary artery (AAOCA) comprises a set of rare congenital abnormalities in the origin or path of the coronary arteries with highly variable clinical implications. This is a pilot feasibility study where we investigated the influence of the anomalous coronary artery inlet architecture on coronary perfusion using coronary blood flow computational simulations to help predict the risk for coronary ischemia in patients with anomalous aortic origin of the right coronary artery (AAORCA) with these types of anomalous coronary artery inlet architectures. We developed a protocol for generating 3D models of patient coronary artery anatomies from an IRB-approved dataset of cardiac CT images of patients with AAORCA at our institution.

View Article and Find Full Text PDF

Introduction: High-Flow Nasal Therapy (HFNT) is an innovative non-invasive form of respiratory support. Compared to standard oxygen therapy (SOT), there is an equipoise regarding the effect of HFNT on patient-centred outcomes among those at high risk of developing postoperative pulmonary complications after undergoing cardiac surgery. The NOTACS trial aims to determine the clinical and cost-effectiveness of HFNT compared to SOT within 90 days of surgery in the United Kingdom, Australia, and New Zealand.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!