Unlabelled: The first aim of the present study was to characterize the systemic and fibrin-specific lytic effect of reteplase in the treatment of patients with acute myocardial infarction. The second aim was to investigate the relation of hemostasis variables to risk of bleeding complications and to coronary patency. The present study is a hemostatic substudy of the German Recombinant Activator Study. Forty two patients have been treated with 10 MU of reteplase (Group A) and 100 patients with 15 MU of reteplase (Group B), given as a single bolus. Blood samples for assessment of fibrinogen, plasminogen, alpha-2-antiplasmin, fibrinogen degradation products (FDP) and D-dimers were obtained before and at 2, 4, 8, and 24 h after thrombolytic therapy. The median fibrinogen concentration was decreased from 279 to 169 mg/dl in Group A and from 254 to 92 mg/dl in Group B four hours after administration of reteplase. The decrease in fibrinogen was significantly more pronounced in Group B (P=0.0004). The median plasminogen concentration was decreased to 53% in Group A and to 33% in Group B two hours after administration of reteplase (P=0.0001). Alpha-2-antiplasmin was reduced to 27% and 17,5%, respectively (P=0.0007). D-Dimer levels were increased to 5.2 microg/ml in Group A and 11,6 microg/ml in Group B (P=0.02) and FDP levels to 3.0 microg/ml in Group A and 12,6 microg/ml in Group B (P=0.04). Patients with bleeding complications revealed significant lower nadir levels of fibrinogen than patients without bleeding complications (54 mg/dl versus 125.5 mg/dl, P=0.02). There was no significant difference in any hemostatic parameter between patients with patent and nonpatent infarct related arteries.

Conclusions: Reteplase causes a moderate systemic lytic effect comparable with other relative fibrin specific thrombolytic agents. An increase in the dose from 10 to 15 MU is associated with a marked increase in both fibrin specific and systemic lytic effect. Patients with bleeding complications reveal significant lower nadir levels of fibrinogen than patients without bleeding complications. Determination of any hemostatic parameter seems to be no useful method to predict efficacy of thrombolysis in terms of coronary patency in the individual patient.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0167-5273(98)00100-4DOI Listing

Publication Analysis

Top Keywords

bleeding complications
24
microg/ml group
16
patients bleeding
16
coronary patency
12
group
11
hemostasis variables
8
complications coronary
8
patients
8
reteplase group
8
concentration decreased
8

Similar Publications

Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.

J Cardiothorac Surg

January 2025

Cardiac Surgery Center, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Affiliated Hospital of University of Electronic Science and Technology, Chengdu, Sichuan Province, 610072, China.

Objective: To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.

Methods: A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.

View Article and Find Full Text PDF

Iatrogenic intramural esophageal hematoma during EUS-B-FNA procedure.

BMC Pulm Med

January 2025

Unidade de Broncologia e Pneumologia de Intervenção - Instituto Português de Oncologia Francisco Gentil, Coimbra, Portugal.

Background: Esophageal ultrasound with bronchoscope fine needle aspiration (EUS-B-FNA) is a valuable tool for the diagnosis and staging of lung cancer, complementing endobronchial lung ultrasound (EBUS). While generally considered safe, there is a notable lack of comprehensive knowledge within the interventional pulmonology community regarding potential complications.

Case Presentation: We present a case involving a 66-year-old male with squamous cell lung carcinoma undergoing mediastinal staging.

View Article and Find Full Text PDF

Ocular Injuries in Patients with Old Blow-out Fractures Following Blunt Trauma.

Korean J Ophthalmol

January 2025

Department of Ophthalmology, Gil Medical Center, Incheon, Gachon University College of Medicine, Incheon, Korea.

Purpose: To analyze the frequency, and clinical characteristics of ocular injuries in patients with prior blow-out fractures who experience new blunt trauma, and to assess whether old orbital fractures provide a protective effect against subsequent ocular trauma.

Methods: The medical records of 1,315 ocular trauma patients were reviewed. A total of 927 patients who had orbital or facial CT scans and ophthalmologist evaluations were considered.

View Article and Find Full Text PDF

Early outcomes of robotic vs open living donor right hepatectomy in a US Center.

Surg Endosc

January 2025

Division of Transplant Surgery, Department of Surgery, Hume- Lee Transplant Center, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.

Background: Robotic living donor hepatectomy offers potential advantages but has been limited to high-volume centers, primarily in Asia and the Middle East. We report our experience establishing a robotic living donor right hepatectomy program in a U.S.

View Article and Find Full Text PDF

We report a female patient in her 70s with mild cognitive impairment due to Alzheimer's disease (AD) who developed a left temporal lobar haemorrhage after the third dose of lecanemab, accompanied by non-traumatic haemorrhage in a pre-existing subdural hygroma, and was diagnosed with amyloid-related imaging abnormalities with haemorrhage. The patient exhibited mild verbal paraphasia and word recall difficulty but had no other major neurological deficits. There was no additional intracranial abnormality during the course of hospitalisation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!