A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percutaneous biopsy in diffuse renal disease: comparison of 18- and 14-gauge automated biopsy devices. | LitMetric

Percutaneous biopsy in diffuse renal disease: comparison of 18- and 14-gauge automated biopsy devices.

J Vasc Interv Radiol

Department of Diagnostic Imaging, Rhode Island Hospital, Brown University School of Medicine, Providence 02903, USA.

Published: October 1998

Purpose: To compare 18-gauge-needle automated biopsy guns to 14-gauge systems for diagnostic efficacy and safety in percutaneous renal biopsy.

Materials And Methods: One hundred sixty-one computed tomographic (CT) guided biopsies for diffuse renal disease were retrospectively reviewed. An automated biopsy gun with an 18-gauge needle was used in 74 procedures, and a 14-gauge needle was used in 87 cases.

Results: Adequate tissue for histologic diagnosis was obtained in 96% (71 of 74) of cases with use of the 18-gauge needle, compared with 99% (86 of 87) in the 14-gauge group. The mean glomeruli per specimen were 10.7 and 13.7, respectively. Major hemorrhagic complications occurred in two cases (2.7%) of the 18-gauge group and in three cases (3.4%) of the 14-gauge group.

Conclusion: The use of a biopsy gun with an 18-gauge needle provides high tissue recovery rate, comparable to that with the 14-gauge system. The complication rate was acceptably low, with no statistically significant difference from the 14-gauge needles (P = .80).

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1051-0443(98)70338-0DOI Listing

Publication Analysis

Top Keywords

automated biopsy
12
18-gauge needle
12
diffuse renal
8
renal disease
8
biopsy gun
8
gun 18-gauge
8
14-gauge
7
percutaneous biopsy
4
biopsy diffuse
4
disease comparison
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!