Background And Purpose: Accurate contouring of the clinical target volume (CTV) is a fundamental prerequisite for successful conformal radiotherapy of prostate cancer. The purpose of this study was to investigate intra- and inter-observer variability in contouring prostate (P) and seminal vesicles (SV) and its impact on conformal treatment planning in our working conditions.

Materials And Methods: Inter-observer variability was investigated by asking five well-trained radiotherapists of contouring on CT images the P and the SV of six supine-positioned patients previously treated with conformal techniques. Short-term intra-observer variability was assessed by asking the radiotherapists to contour the P and SV of one patient for a second time, just after the first contouring. The differences among the inserted volumes were considered for both intra- and inter-observer variability. Regarding intra-observer variability, the differences between the two inserted contours were estimated by taking the relative differences in correspondence to the CT slices on BEV plots (antero-posterior and left-right beams). Concerning inter-observer variability, the distances between the internal and external envelopes of the inserted contours (named projected diagnostic uncertainties or PDUs) and the distances from the mean inserted contours (named mean contour distances or MCDs) were measured from BEV plots (i.e. parallel to the CT slices).

Results: Intra-observer variability was relatively small (the average percentage variation of the volume was approximately 5%; SD of the differences measured on BEV plots within 1.8 mm). Concerning inter-observer variability, the percentage SD of the inserted volumes ranged from 10 to 18%. Differences equal to 1 cm in the cranio-caudal extension of P + SV were found in four out of six patients. The largest inter-observer variability was found when considering the anterior margin in the left-right beam of P top (MCD = 7.1 mm, 1 SD). Relatively high values for MCDs were also found for P bottom, for the posterior and lateral margins of P top (2.6 and 3.1 mm, respectively, I SD) and for the anterior margin of SV (2.8 mm, 1 SD). Relatively small values were found for P central (from 1.4 to 2.0 mm, 1 SD) and the posterior margin of SV (1.5 mm, 1 SD).

Conclusions: The application of larger margins taking inter-observer variability into account should be taken into consideration for the anterior and the lateral margins of SV and P top and for the lateral margin of P. The impact of short-term intra-observer variability does not seem to be relevant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0167-8140(98)00021-8DOI Listing

Publication Analysis

Top Keywords

inter-observer variability
32
intra-observer variability
16
intra- inter-observer
12
variability
12
inserted contours
12
bev plots
12
variability contouring
8
contouring prostate
8
prostate seminal
8
seminal vesicles
8

Similar Publications

CardiacField: computational echocardiography for automated heart function estimation using two-dimensional echocardiography probes.

Eur Heart J Digit Health

January 2025

Department of Cardiovascular Surgery of Zhongshan Hospital, Fudan University, Shanghai 200032, China.

Aims: Accurate heart function estimation is vital for detecting and monitoring cardiovascular diseases. While two-dimensional echocardiography (2DE) is widely accessible and used, it requires specialized training, is prone to inter-observer variability, and lacks comprehensive three-dimensional (3D) information. We introduce CardiacField, a computational echocardiography system using a 2DE probe for precise, automated left ventricular (LV) and right ventricular (RV) ejection fraction (EF) estimations, which is especially easy to use for non-cardiovascular healthcare practitioners.

View Article and Find Full Text PDF

The assessment of biological maturation is a central topic in pediatric exercise sciences. Skeletal age (SA) reflects changes in each bone of the hand and wrist from initial ossification to the adult state. This study examined intra-observer and inter-examiner agreement is Greulich-Pyle (GP) assessments of SA in 97 male tennis players 8.

View Article and Find Full Text PDF

The aim of this study was to validate the performance of the A&D UA-1100NFC hoseless devices of two cuff sizes in monitoring blood pressure (BP) in the upper arm according to the International Organization for Standardization (ISO) 81060-2:2018/amendment (Amd) 1:2020 protocol. The accuracy of the UA-1100NFC (for arm circumferences of 22.0-32.

View Article and Find Full Text PDF

Objective: Laryngoscopy, essential for diagnosing laryngeal cancer (LCA), faces challenges due to high inter-observer variability and the reliance on endoscopist expertise. Distinguishing precancerous from early-stage cancerous lesions is particularly challenging, even for experienced practitioners, given their similar appearances. This study aims to enhance laryngoscopic image analysis to improve early screening/detection of cancer or precancerous conditions.

View Article and Find Full Text PDF

Accurate melanoma diagnosis is crucial for patient outcomes and reliability of AI diagnostic tools. We assess interrater variability among eight expert pathologists reviewing histopathological images and clinical metadata of 792 melanoma-suspicious lesions prospectively collected at eight German hospitals. Moreover, we provide access to the largest panel-validated dataset featuring dermoscopic and histopathological images with metadata.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!