Purpose: To evaluate objectively the effects of a microbubble contrast agent on the color Doppler ultrasound (US) examination of breast lesions.

Materials And Methods: Forty-seven patients aged 23-71 years underwent color Doppler US before and after intravenous injection of a microbubble contrast agent. A 3-minute computer-assisted assessment of the color pixel density (CPD) was used to evaluate objectively the increase in the number of color Doppler US signals, the transit time of the microbubble bolus, and the potential additional differential diagnostic information.

Results: Peak CPD at contrast agent-enhanced color Doppler US was 14.3% +/- 8.1 (mean +/- 1 standard deviation) for carcinomas and 9.3% +/- 4.9 for benign lesions (P = .04). The time to peak enhancement was shorter in carcinomas (38 seconds +/- 20) than in benign tumors (71 seconds +/- 48, P = .02). Final CPD was close or equal to baseline values. With the median of 13% for peak CPD as a threshold, the sensitivity for this parameter was 55%, the specificity was 79%, and the accuracy was 62% (P = .04). For a median time to peak of 50 seconds, the sensitivity was 84%, the specificity was 57%, and the accuracy was 76%.

Conclusion: After microbubble contrast agent injection, carcinomas and benign lesions behave differently in degree, onset, and duration of Doppler US enhancement. High interindividual variability and temporal variations in the Doppler US signal still limit the value of these criteria for prospective diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.208.2.9680580DOI Listing

Publication Analysis

Top Keywords

color doppler
20
microbubble contrast
16
contrast agent
16
effects microbubble
8
assessment color
8
evaluate objectively
8
peak cpd
8
+/- benign
8
benign lesions
8
time peak
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!