Elecsys assays for the cardiac markers Troponin T (cTnT) and CK-MB have been evaluated in an international multicenter study on the random access analyzer Elecsys 2010 to characterize their clinical performance and their comparability with respective established routine methods. In method comparison studies of Elecsys Troponin T (TnT) with Enzymun-Test TnT, good correlations (r > or = 0.95) and a high degree of correspondence (slopes in 4 laboratories between 0.95 and 1.05) were found. The method comparison studies of Elecsys CK-MB with various CK-MB routine methods lead to good correlations but some systematic deviation in the slopes due to varying standardization. In a reference population of 350 persons upper reference limits (97.5th percentile) of 0.03 milligrams/l for Elecsys TnT and 3.1 milligrams/l for Elecsys CK-MB were found. In cardiosensitivity studies the equivalent diagnostic information of the new Elecsys assays to routine methods was confirmed in the early diagnosis of acute myocardial infarction (AMI), the detection of minor myocardial damages in patients with unstable angina pectoris (UAP) and in time course data monitoring of AMI and bypass surgery patients. The superior sensitivity of cTnT versus CK-MB has been established in a screening situation where in 29 patients with cardiac diseases only cTnT, but not CK-MB, was found pathologically increased; this was due either to the larger diagnostic window of cTnT in AMI or to the more sensitive recognition of minor myocardial damage. In the same study, the cardiospecificity of Elecsys TnT was found to be at least 99.5%. This has also been demonstrated in an earlier study for Enzymun-Test TnT. Further cardiospecificity testing, e.g. in renal failure patients, showed results equivalent to those of Enzymun-Test TnT. An extended clinical study involving 294 patients with chest pain, of whom 58 had a final diagnosis of AMI, revealed highly comparable sensitivity and specificity for the Elecsys assays and routine methods. Thus, the already recommended clinical cut-off values of 0.1 milligrams/l for cTnT and 5 milligrams/l for CK-MB are also valid for the Elecsys assays. The slightly improved sensitivity of Elecsys TnT in the lower range even allows the recognition of pathological increase at cTnT concentrations below 0.1 milligrams/l in special situations with sufficient additional clinical information. Summarizing, provide the two cardiac markers on the Elecsys 2010 at least equivalent or even superior diagnostic information in various clinical situations of cardiac disease compared with routine methods. The short turn-around time and reliable performance qualify the Elecsys assays as new methods of choice for routine and emergency use.

Download full-text PDF

Source

Publication Analysis

Top Keywords

elecsys assays
20
routine methods
20
elecsys
14
cardiac markers
12
elecsys 2010
12
enzymun-test tnt
12
elecsys tnt
12
clinical performance
8
markers troponin
8
ck-mb
8

Similar Publications

Background: Serum B-cell maturation antigen (sBCMA) levels have emerged as a potential biomarker for disease monitoring in multiple myeloma (MM) with prognostic value.

Methods: Herein, we evaluated the sBCMA levels in 166 patients with newly diagnosed MM with an Elecsys-based sBCMA assay.

Results: Increased sBCMA levels at diagnosis were correlated with inferior survival outcomes in terms of both progression-free and overall survival.

View Article and Find Full Text PDF

We investigated whether antibody concentrations measured in plasma using the Roche Elecsys® Anti-SARS-CoV-2 S assay (targeting the receptor binding domain, RBD) could estimate levels of Wuhan-Hu-1 and Omicron XBB.1.5 spike-directed antibodies with neutralizing ability (NtAb) or those mediating NK-cell activity.

View Article and Find Full Text PDF

Background And Aims: Dried blood spots (DBS) have been proposed as a cost-effective surveillance method for population-wide screening of SARS-CoV-2 immunity but sensitivity of DBS based on self-collected DBS samples is unknown. To evaluate the success of vaccination strategies, it is necessary to differentiate vaccination from natural infection. Therefore, a test for antibodies against the viral nucleocapsid protein (anti-N) is desirable.

View Article and Find Full Text PDF

Background And Objectives: Blood-based biomarkers of amyloid and tau have been shown to predict Alzheimer disease (AD) dementia. Much less is known about their ability to predict risk of mild cognitive impairment (MCI), an earlier disease stage. This study examined whether levels of blood biomarkers of amyloid (Aβ/Aβ ratio), tau (p-tau), neurodegeneration (NfL), and glial activation and neuroinflammation (glial fibrillary acidic protein [GFAP], YKL40, soluble triggering receptor expressed on myeloid cells 2 [sTREM2]) collected when participants were cognitively normal are associated with the time to onset of MCI.

View Article and Find Full Text PDF

Introduction: The use of antibody titers against SARS-CoV-2, as a method of estimating subsequent infection following infection or vaccination, is unclear. Here, we investigate whether specific levels of antibodies, as markers of adaptive immunity, can serve to estimate the risk of symptomatic SARS-CoV-2 (re-) infection.

Methods: In this real-world study, laboratory data from individuals tested for SARS-CoV-2 antibodies under routine clinical conditions were linked through tokenization to a United States medical insurance claims database to determine the risk of symptomatic/severe SARS-CoV-2 infection outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!