A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of mycophenolic acid and its glucuronide in human plasma using a simple high-performance liquid chromatography procedure. | LitMetric

We describe a reversed-phase HPLC method for determination of total mycophenolic acid (MPA), its free concentration (MPAf), and the glucuronide metabolite (MPAG), based on simple sample preparation and gradient elution chromatography. The compounds were quantified in parallel by absorbance at 254 nm and 215 nm in the internal standard mode. Linearity was verified up to 50 mg/L for MPA and up to 500 mg/L for MPAG (r >0.999). Detection limits at 215 and 254 nm were, respectively, 0.01 and 0.03 mg/L for MPA, and 0.03 and 0.1 mg/L for MPAG. The recovery of MPA was 95-106%; recovery of MPAG was 96-106%. The imprecision (CV) for MPA (0.2-25 mg/L) was <8.4% (254 nm) and <4.4% (215 nm) within day (n = 12) and <9.2% (254 nm) and <6.2% (215 nm) between days (n = 12). The imprecision for MPAG (10-250 mg/L) was <4.9% (254 nm) and <3.4% (215 nm) within day, and <6.1% (254 nm) and <5.9% (215 nm) between days. For quantification of MPAf, 100 microL of ultrafiltrate was applied directly to the column. The detection limit was 0.005 mg/L at 215 nm and 0.015 mg/L at 254 nm. In the range between 18-210 microg/L, the within-day CVs were <11.8% (n = 12) and the between-day CVs were <15.8% (n = 12).

Download full-text PDF

Source

Publication Analysis

Top Keywords

mycophenolic acid
8
mg/l mpa
8
mg/l mpag
8
003 mg/l
8
mpa
5
mg/l
5
simultaneous determination
4
determination mycophenolic
4
acid glucuronide
4
glucuronide human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!