Purpose: To present our results with the minimally invasive thoracotomy (MIT) in patients with valve disease and to describe a new type of thoracotomy.

Methods: Twenty-five patients with valve disease as the major cardiac problem were operated during a five month period. Two types of incisions were used: one in an inverted-T fashion and another in a H fashion. Fourteen patients were submitted to an inverted-T incision and eleven to a H incision. In 24% of the patients reoperation was being performed.

Results: The incisions ranged from 7.5 to 11 cm (mean 9.1 cm), mean ICU stay was 31 h and hospital stay 4.8 days. In all but one patient the operation could be adequately in performed through the MIT, in only one patient total sternotomy had to be performed.

Conclusion: The MIT may have some advantages such as, better aesthetic results, less pain and more sternal stability. These factors may improve early extubation and decrease hospital stay. The H type incision allows an adequate exposition of the most central part of the chest and all heart valves with adequate exposure. This technique led to no complications during reoperations and we believe it to be as safe as the total sternotomy.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0066-782x1998000200001DOI Listing

Publication Analysis

Top Keywords

patients valve
8
valve disease
8
hospital stay
8
total sternotomy
8
[partial median
4
median sternotomy
4
sternotomy approach
4
approach cardiac
4
cardiac surgery]
4
surgery] purpose
4

Similar Publications

Superficial arteriovenous malformations are rare fast-flow lesions. They consist of arteriovenous shunts, without cellular hyperplasia or proliferation, which develop in the surrounding tissues (cutaneous, subcutaneous, muscular, bone). Although benign, they are among the most severe of superficial malformations.

View Article and Find Full Text PDF

Fetal cardiac function in pregnancy affected by congenital heart disease: protocol for a multicentre prospective cohort study.

BMC Pregnancy Childbirth

January 2025

Royal Hospital for Women and UNSW, School of Clinical Medicine, Level 0, Royal Hospital for Women, Barker Street (Locked Bag 2000), Sydney, NSW, 2031, Australia.

Background: Congenital heart disease (CHD) is the most common fetal malformation, and it can result first in cardiac remodeling and dysfunction and later in cardiac failure and hydrops. A limited number of studies have evaluated cardiac function in fetuses affected by CHD. Functional parameters could potentially identify fetuses at risk of cardiac failure before its development.

View Article and Find Full Text PDF

Background: Mitral valve repair (MVr) is the gold standard treatment for degenerative mitral regurgitation, yet there is ongoing controversy regarding optimal anti-thrombotic therapy post-MVr. This scoping review aimed to summarise current evidence on the safety and efficacy of anti-thrombotic therapy after MVr, identify knowledge gaps and propose a future study design.

Methods: We searched MEDLINE, Embase, Cochrane Central Register of Controlled Trials, Clinicaltrials.

View Article and Find Full Text PDF

Background: Training in complex high-risk indicated percutaneous coronary intervention (CHIP-PCI) has frequently been reserved for established operators (consultants/attending) with trainees (fellows-in-training or FIT) being often discouraged from carrying out such procedures as a primary operator due to their high-risk nature. Whether the outcomes of these cases differ if the primary operator is a supervised FIT compared with a consultant is unknown.

Methods: Using multicentre PCI data from three cardiac centres in South Wales, UK (2018-2022), we identified 2295 CHIP-PCI cases with a UK-BCIS CHIP Score of 3 or more.

View Article and Find Full Text PDF

Background: Current guidelines recommend transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis and porcelain aorta (PA). Neurological outcomes of patients with PA undergoing TAVI with modern valves require clarification as most trials examined balloon-expandable valves (BEV) and self-expandable valves in intermediate or high-risk patients, but not specifically in patients with PA. Our aim was to compare outcomes, including stroke and mortality, in well-matched patients with and without PA who received BEV during transfemoral TAVI procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!