Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1365-2044.1998.tb15159.x | DOI Listing |
Chem Commun (Camb)
January 2025
Chemistry Department, Shiraz University, Shiraz, Iran.
Coagulation disorders can lead to dangerous bleeding or clot formation. Since centralized laboratories cannot provide rapid results for timely treatment intervention in patients with coagulation disorders, the existence of coagulation sensors for the general public is necessary. The purpose of the present research is to design and fabricate a novel, portable, low-cost, paper-based colorimetric sensor for measuring blood prothrombin time.
View Article and Find Full Text PDFAnesth Analg
January 2025
From the Department of Anesthesiology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands.
Background: Rotational thromboelastometry (ROTEM) is widely used for point-of-care coagulation testing to reduce blood transfusions. Accurate interpretation of ROTEM data is crucial and requires substantial training. This study investigates the inter- and intrarater reliability of ROTEM interpretation among experts and compares their interpretations with a ROTEM-guided algorithm.
View Article and Find Full Text PDFJ Zhejiang Univ Sci B
January 2025
Department of Clinical Laboratory, Guangzhou Institute of Respiratory Health, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Laboratory, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510140, China.
The accurate and timely detection of biochemical coagulation indicators is pivotal in pulmonary and critical care medicine. Despite their reliability, traditional laboratories often lag in terms of rapid diagnosis. Point-of-care testing (POCT) has emerged as a promising alternative, which is awaiting rigorous validation.
View Article and Find Full Text PDFAdv Healthc Mater
January 2025
Antimicrobial Research Laboratory, New Chemistry Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Jakkur, Bengaluru, Karnataka, 560064, India.
Uncontrollable haemorrhage and associated microbial contamination in the battlefield and civilian injuries pose a tremendous threat to healthcare professionals. Such traumatic wounds often necessitate an effective point-of-care solution to prevent the consequent morbidity owing to blood loss or haemorrhage. However, developing superior hemostatic materials with anti-infective properties remains a challenge.
View Article and Find Full Text PDFBioact Mater
April 2025
Department of Orthopedic Surgery, First People's Hospital of Foshan, Foshan, Guangdong, 528000, PR China.
Uncontrollable non-compressible hemorrhage and traumatic infection have been major causes of mortality and disability in both civilian and military populations. A dressing designed for point-of-care control of non-compressible hemorrhage and prevention of traumatic infections represents an urgent medical need. Here, a novel self-gelling sponge OHN@ε-pL is developed, integrating N-succinimidyl ester oxidized hyaluronic acid (OHN) and ε-poly-L-lysine (ε-pL).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!