Ideally electrical impedance tomography (EIT) should not be oversensitive to electrode positions, but this conflicts with efforts to produce high-resolution images. Two procedures are presented that balance reducing the sensitivity to electrode position errors with generating practicable EIT images. The first provides a criterion based on electrode sensitivity for regularizing the reconstruction through spectral expansion. The main consequences of this are that smoother images are produced and the number of artefacts and their magnitude are generally reduced. The second modification uses the recorded data to compensate for electrode movements that have occurred after the reference data were measured. Image smoothness is used as the criterion for the readjustment. Computer simulation tests have shown that this modification produces improved image fidelity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/43/6/025 | DOI Listing |
Future Cardiol
January 2025
Department of Internal Medicine, Dow University of Health Sciences, Karachi, Pakistan.
Background: Implantable cardioverter-defibrillators (ICDs) are essential for reducing sudden cardiac death in patients at risk of ventricular arrhythmias. The choice of ICD lead - single-coil or dual-coil - can influence device performance and patient outcomes. This meta-analysis evaluates the comparative efficacy and safety of single-coil versus dual-coil ICD leads to inform clinical decision-making.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).
View Article and Find Full Text PDFAnnu Rev Chem Biomol Eng
January 2025
Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, Norrköping, Sweden; email:
Organic mixed ionic-electronic conductors (OMIECs) could revolutionize bioelectronics by enabling seamless integration with biological systems. This review explores their role in neural biomimicry and biointerfacing, with a focus on how backbone design, sidechain optimization, and antiambipolarity impact performance. Recent advances highlight OMIECs' biocompatibility and mechanical compliance, making them ideal for bioelectronic applications.
View Article and Find Full Text PDFCien Saude Colet
January 2025
Escola Nacional de Saúde Pública, Fundação Oswaldo Cruz. Rio de Janeiro RJ Brasil.
The scope of this study was to determine the diagnostic performance of ABSI for obesity and sarcopenic obesity, compared to the results of bioimpedance analysis (BIA) and BMI, by sex and age group. It involved a cross-sectional study with 12,793 participants in the second round of ELSA-Brasil (Longitudinal Study of Adult Health in Brazil), which obtained measurements of body fat percentage using BIA and anthropometry, verifying the performance of the diagnostic tests in order to compare the indices. The results showed that for obesity in men in all three age groups, the sensitivity was below 49%.
View Article and Find Full Text PDFTrop Biomed
December 2024
Department of Critical Care Medicine, The Fourth Affiliated Hospital, School of Medicine, Zhejiang University, No. N1 Shangcheng Avenue, Yiwu, Zhejiang 322000, China.
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi. It is transmitted through bite of chigger mite larvae and presents with symptoms such as fever, myalgia, headache, rash, and a characteristic eschar at the site of mite bites. This report details the case of a woman exhibiting acute febrile illness, bilateral pneumonia, and severe hypoxemia, prompting suspicion of scrub typhus due to the presence of a typical eschar on the pubic mound.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!