Unlabelled: Our objective was to build and test a new system for transmission CT (TCT) imaging on a three-headed SPECT camera. The TCT images are intended for use in nonuniform attenuation correction of cardiac SPECT data.
Methods: The system consists of a transmission line source mounted to the camera gantry at the focal line of a long focal length, asymmetric fanbeam collimator. The focal line is 114 cm from the collimator surface and shifted 20 cm from the detector midline. This asymmetric fanbeam geometry is used to reduce truncation artifacts in the reconstructed TCT image. The line source fixture accommodates a 25-cm long source and contains removable, variable thickness attenuator plates (copper or lead) to modulate the photon flux density and a slat collimator to collimate the TCT source beam in the axial direction. For the TCT reconstruction, an iterative maximum likelihood-expectation maximization algorithm is used that models the asymmetric fanbeam geometry. Our initial studies with this system used a 1850 MBq (50 mCi) 123mTe line source. The evaluation included TCT scans of a resolution phantom, an anthropomorphic thorax phantom and a human subject. For the thorax phantom and human subject, short (2-min) and long (14-min) scans were performed. The SPECT imaging performance of the fanbeam collimator was also characterized.
Results: For both phantom and human data, high quality TCT reconstructions were obtained with linear attenuation coefficients closely matching narrow beam values. In the images of the resolution phantom, the smallest rods (4.8-mm diam) were resolved. The long scan images of the thorax phantom and human subject demonstrated the high resolution nature of the system and contained no evidence of truncation artifacts. With smoothing to control noise, the short scan images generally retained the attenuation features of the lung and of soft tissue and may provide a practical approach for clinical application. The fanbeam collimator demonstrated high resolution SPECT performance.
Conclusion: These results suggest this system may provide an effective and practical approach to TCT imaging for nonuniform attenuation correction on a three-headed SPECT camera.
Download full-text PDF |
Source |
---|
Sensors (Basel)
January 2025
School of Biomedical Engineering and Imaging Sciences, King's College London, London SE1 7EH, UK.
Ultrasound imaging is widely valued for its safety, non-invasiveness, and real-time capabilities but is often limited by operator variability, affecting image quality and reproducibility. Robot-assisted ultrasound may provide a solution by delivering more consistent, precise, and faster scans, potentially reducing human error and healthcare costs. Effective force control is crucial in robotic ultrasound scanning to ensure consistent image quality and patient safety.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel, 1050 Brussels, Belgium.
Fluorescence imaging has been widely used in fields like (pre)clinical imaging and other domains. With advancements in imaging technology and new fluorescent labels, fluorescence lifetime imaging is gradually gaining recognition. Our research department is developing the CAM, based on the Current-Assisted Photonic Sampler, to achieve real-time fluorescence lifetime imaging in the NIR (700-900 nm) region.
View Article and Find Full Text PDFElife
December 2024
Centre for Cognitive Neuroscience and Department of Psychology, Paris-Lodron-University of Salzburg, Salzburg, Austria.
Phantom perceptions like tinnitus occur without any identifiable environmental or bodily source. The mechanisms and key drivers behind tinnitus are poorly understood. The dominant framework, suggesting that tinnitus results from neural hyperactivity in the auditory pathway following hearing damage, has been difficult to investigate in humans and has reached explanatory limits.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
College of Optometry, University of Houston, Houston, TX, USA.
Purpose: To characterize frequency-dependent wave speed dispersion in the human cornea using microliter air-pulse optical coherence elastography (OCE), and to evaluate the applicability of Lamb wave theory for determining corneal elastic modulus using high-frequency symmetric (S0) and anti-symmetric (A0) guided waves in cornea.
Methods: Wave speed dispersion analysis for transient (0.5 ms) microliter air-pulse stimulation was performed in four rabbit eyes ex vivo and compared to air-coupled ultrasound excitation.
Eur J Trauma Emerg Surg
January 2025
Department of Orthopedic, Trauma and Reconstructive Surgery, Percy Military Hospital, 101 Avenue Henri Barbusse, Clamart, 92140, France.
Introduction: Targeted muscle reinnervation (TMR) is a technique that has proven effective for the treatment and prevention of chronic pain following amputation, though its adoption remains limited. The authors report on their initial experience using TMR.
Methods: A prospective study was conducted in a military trauma center involving traumatic amputees treated with either curative or preemptive TMR.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!