The silicone breast implant controversy rages on. Recent work has demonstrated that normal or baseline breast tissue silicon levels in women who had had no prior exposure to any type of breast implant may be as high as 446 microg/gm of tissue. These data ranged from 4 to 446 microg/gm of tissue, with a median of 27.0 microg/gm of tissue. In addition, numerous other epidemiologic and rheumatologic studies have demonstrated no association between silicone breast implants and any connective-tissue diseases. Despite these reports, the use of silicone implants remains restricted. The present study measured breast and capsular tissue silicon levels from 23 breasts in 14 patients with saline implants, and from 42 breasts in 29 patients with silicone implants. No patient in the saline implant group presented with signs or symptoms of connective-tissue disease. Patients with silicone implants, however, were divided into three groups based on the presence or absence of signs or symptoms of connective-tissue disease: group I, no symptoms or signs; group II, + symptoms, no signs; and group III, + symptoms, + signs. Six patients in group III were diagnosed with a specific connective-tissue disease, including systemic lupus erythematosus, rheumatoid arthritis, or scleroderma. The most common indications for implant removal or exchange were capsular contracture and implant rupture, although 41 percent of patients with silicone implants expressed media-related concern over the implant issue. The most common symptoms described by patients in groups II and III were joint pain and stiffness, arm pain and numbness, and fatigue. In all groups, capsular tissue silicon levels were significantly greater than breast tissue levels. This finding may indicate that the capsule serves as a barrier to the distribution of silicone from the implant into adjacent breast tissue. Although breast tissue silicon levels in patients with silicone implants were not significantly greater than those in patients with saline implants (p = 0.48), capsular tissue levels in patients with silicone implants were, indeed, significantly greater than those in patients with saline implants (p < 0.001). However, no statistically significant differences in tissue silicon levels were observed with relation to the presence or absence of connective-tissue disease signs or symptoms in patients with silicone implants (groups I to III). Therefore, these data strengthen the conclusion that there is no association between tissue silicon levels and connective-tissue disease.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00006534-199806000-00009DOI Listing

Publication Analysis

Top Keywords

silicone implants
28
connective-tissue disease
24
tissue silicon
24
silicon levels
24
patients silicone
24
capsular tissue
16
patients saline
16
breast tissue
16
tissue
13
patients
12

Similar Publications

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Antimicrobial Silicon Rubber Crosslinked with Bornyl-Siloxane.

Macromol Rapid Commun

January 2025

State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, P. R. China.

Silicone rubber (SiR) has a wide range of medical applications, but it lacks antimicrobial properties, leading to potential infection issues with related implants or medical devices. Most studies focus on adding anti-bacterial agents or surface modification, which usually result in composites with anti-bacterial properties, rather than synthesizing SiR with intrinsically antimicrobial performances. To tackle this issue, a double substituted bornyl-siloxane crosslinker (BC) is designed.

View Article and Find Full Text PDF

Full-arch implant-supported rehabilitation using reverse scan technique: A case report.

J Oral Implantol

January 2025

Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.

The reverse scan technique offers several advantages, such as improvements of accuracy and visibility of critical anatomical structures, minimizing chair time, and providing better patient comfort. This was a case report successfully employing the reverse scan technique. A 72-year-old male patient desired to restore his teeth in both jaws, as he experienced difficulty eating and had never worn dentures.

View Article and Find Full Text PDF

The aim of this work is to incorporate lanthanide-cored upconversion nanoparticles (UCNP) into the surface of microengineered biomedical implants to create a spatially controlled and optically releasable model drug delivery device in an integrated fashion. Our approach enables silicone-based microelectrocorticography (ECoG) implants holding platinum/iridium recording sites to serve as a stable host of UCNPs. Nanoparticles excitable in the near-infrared (lower energy) regime and emitting visible (higher energy) light are utilized in a study.

View Article and Find Full Text PDF

Biofilm formation on prostheses and implanted devices can lead to serious complications and increased healthcare expenditures. Once formed, biofilm management is difficult and may involve a long course of antibiotics, additional surgery, and, occasionally, implant removal. This study evaluated the antibacterial properties of medical-grade silicone samples integrated with novel, non-leaching, antibacterial, quaternary ammonium silica (QASi) particles.