Thrombotic obstruction of mechanical prosthetic valves is a frequently encountered cause of prosthetic valve dysfunction, which can result in stenosis and regurgitation. We present a case of thrombotic obstruction of a bileaflet mechanical aortic valve prosthesis that resulted in severe stenosis and regurgitation. Considering the known risk factors associated with both surgical and thrombolytic treatments, a decision was made to use tissue plasminogen activator therapy to relieve the burden of the thrombotic valvular obstruction. In this case review, we use continuous wave Doppler to demonstrate recovery of normal valve function despite suboptimal two-dimensional imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(98)70028-8DOI Listing

Publication Analysis

Top Keywords

aortic valve
8
valve prosthesis
8
tissue plasminogen
8
plasminogen activator
8
activator therapy
8
continuous wave
8
wave doppler
8
thrombotic obstruction
8
stenosis regurgitation
8
evaluation bileaflet
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!