The purpose of this study was to evaluate all post extracorporeal membrane oxygenation (ECMO) tests for their ability to detect any change in the incidence of unanticipated medical problems, and their charge to the patient. The current post ECMO protocol consists of the following tests: brain stem auditory evoked response, head computed tomography, cerebral blood flow, head ultrasonography, electroencephalography, eye examination for retinopathy of prematurity, and pneumocardiography. A retrospective review was conducted for all surviving neonatal ECMO patients treated from January, 1985, to December, 1994. The results of each test were classified as either normal, having a minor abnormality, or having a major abnormality. Statistical analyses were performed on each test comparing the incidence of minor and major abnormalities to all neonates in the neonatal intensive care nursery. Two hundred ninety-six infants survived their course on ECMO, and composed the study population. There were no significant differences between the incidence of abnormal results compared with the expected values for the following tests: cerebral blood flow (p=0.13), the eye examination (p=0.54), and pneumocardiography (p=0.22). The analyses for the brain stem auditory response, head computed tomography, head ultrasonography, and electroencephalography showed higher than expected incidences of abnormal results (p < 0.01). The data also were evaluated for major abnormalities on computed tomography and head ultrasonography. Of 161 infants who had both tests performed, 11 (6.8%) had normal head ultrasonography results, yet had a major abnormality noted on computed tomography (p < 0.01). This study is the first to review the current post ECMO protocol comprehensively, and the results suggest excluding the cerebral blood flow, eye, and pneumocardiography tests. This would result in a significant savings of $1,400 without compromising patient care. In addition, comparisons of neuroradiographic studies indicate that computed tomography of the head is sensitive enough to detect all central nervous system abnormalities that were found by ultrasonography. Excluding the post ECMO head ultrasonography, an additional savings of $300 would occur. These recommended changes reflect the current post ECMO protocol at Kosair Children's Hospital.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00002480-199805000-00009 | DOI Listing |
Oper Neurosurg (Hagerstown)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.
View Article and Find Full Text PDFASAIO J
January 2025
From the Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
The use of cardiac devices, including mechanical circulatory support (MCS), cardiac implantable electronic devices (CIEDs), and pacing wires, has increased and significantly improved survival in patients with severe cardiac failure. However, these devices are frequently associated with acute brain injuries (ABIs) including ischemic strokes, intracranial hemorrhages, seizures, and hypoxic-ischemic brain injury which contribute substantially to morbidity and mortality. Computed tomography (CT) and magnetic resonance imaging (MRI), the standard imaging modalities for ABI diagnosis, can pose significant challenges in this patient population due to the risks associated with patient transportation and the incompatibility of ferromagnetic components of certain cardiac devices with high magnetic field of the MRI.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Cedars Sinai Medical Center, Los Angeles, California.
Case: A 14-year-old male athlete presented with a 9-month history of low back pain, worse with hyperextension. Nonoperative management for bilateral L4 spondylolysis had been unsuccessful. The patient underwent a novel magnetic resonance imaging (MRI) that generated a synthetic computed tomography (sCT).
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Orthopaedics, PGIMER, Chandigarh, India.
Case: A 30-year-old man presented with left proximal tibia fracture (open Grade 3A) and a transverse lateral malleolus fracture (Weber B) following direct impact injury. Computed tomography revealed a rare posteromedial tubercle fibula fracture at the posterior inferior tibiofibular ligament (PITFL) insertion, with syndesmosis disruption. Initial damage control included an external fixator.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Radiation Physics, Zhejiang Key Laboratory of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, China.
Accurate and efficient automatic segmentation is essential for various clinical tasks such as radiotherapy treatment planning. However, atlas-based segmentation still faces challenges due to the lack of representative atlas dataset and the computational limitations of deformation algorithms. In this work, we have proposed an atlas selection procedure (subset atlas grouping approach, MAS-SAGA) which utilized both image similarity and volume features for selecting the best-fitting atlases for contour propagation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!