Results obtained from blood sample readings by optical microscopy and He-Ne laser (lambda = 630.1 mW), have confirmed the reduction in Heinz Bodies (HB) formation time and the Transmittance Reduction Degree (TRD), in malignancies. The results of spectrometric readings in colorectum polyposis, (TRD = 0.07) and fibrocystic mastopathy (TRD = 0.08) gave results overlapping with controls (TRD = 0.08). In neoplasias, the early HB formation in erythrocytes observed by optical microscope corresponded to TRD increase = 0.17 (P < 0.01). TRD increase was statistically significant (P < 0.01), as well as the reduction in the time of HB appearance (< 0.01). The relationship between optical and laser readings was exponential in tumors, while it was linear in controls, in polyposis and mastopathies. The values of the correlation coefficients obtained by both methods were significant (P < 0.01) for all the studied groups. Moreover, these research data further support the existence, even in the earlier stages of the disease, of the labile state of the red cell membrane due to strong lipid peroxidation by FRs.
Download full-text PDF |
Source |
---|
Photoacoustics
February 2025
Dipartimento di Scienze di Base ed Applicate per l'Ingegneria, Sapienza Università di Roma, Rome 00161, Italy.
A compact and robust optical excitation photoacoustic sensor with a self-integrated laser module excitation and an optimized differential resonator was developed to achieve high sensitivity and full linear range detection of carbon dioxide (CO) based on dual modes of wavelength modulated photoacoustic spectroscopy (WMPAS) and resonant frequency tracking (RFT). The integrated laser module equipped with three lasers (a quantum cascade laser (QCL), a distributed feedback laser (DFB) and a He-Ne laser) working in a time-division multiplexing mode was used as an integrated set of spectroscopic sources for detection of the designated concentration levels of CO. With the absorption photoacoustic mode, the WMPAS detection with the QCL and DFB sources was capable of CO detection at concentrations below 20 %, yielding a noise equivalent concentration (NEC) as low as 240 ppt and a normalized noise equivalent absorption coefficient (NNEA) of 4.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Agricultural, Forest and Transport Machinery, University of Life Sciences in Lublin, Głęboka 28, 20-612, Lublin, Poland.
In this paper, we propose a high-precision dual-comb ranging (DCR) method for short-distance measurement, avoiding carrier-envelope-offset locking. Cross-polarization detection is introduced, which makes better use of the intrinsic coherence of interferogram pairs over a short distance. We analyze the noise in the DCR system and propose a carrier-wave phase difference (CPD) calculation algorithm based on centroid extraction.
View Article and Find Full Text PDFPhotodiagnosis Photodyn Ther
November 2024
Department of Dermatology, Guangzhou Dermatology Hospital (Guangzhou Institute of Dermatology), Guangzhou, Guangdong 510095, China. Electronic address:
Sci Rep
November 2024
Department of Physics, Faculty of Education, Ain Shams University, Roxy, Cairo, 11757, Egypt.
The aqueous solution cast method was used to create the biodegradable polymer nanocomposite (PNC) films from a blend of poly (vinyl alcohol) PVA and poly (vinyl pyrrolidone) PVP (70/30 wt %) and FeO nanoparticles (NPs). These PNC films were characterized using X-ray diffraction, scanning electron microscopy SEM, Fourier transform infrared spectroscopy FTIR, and ultraviolet-visible spectroscopy. XRD and FTIR results indicate that Fe NPs interact with the host polymer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!