High energy phosphate levels fall rapidly during cardiac ischemia and recover slowly (more than one week) during reperfusion. The slow recovery of ATP may reflect a lack of purine metabolic precursors and/or increased activity of purine catabolic enzymes such as 5'-nucleotidase (5'-NT, EC 3.1.3.5) and adenosine deaminase (ADA, EC 3.5.4.4). The activity of enzymes involved in both the catabolism of ATP precursors (5-NT and ADA) and the restoration of ATP from slow synthetic pathways [adenosine kinase (AK, EC 2.7.1.20), adenine phosphoribosyl transferase (APRT, EC 2.4.2.7) and hypoxanthine phosphoribosyl transferase (HPRT, EC 2.4.2.8)] may directly affect the rate of ATP recovery. Strategies to enhance recovery will depend on the relative activity of these enzymes following ischemia. Their activity in different species and their response to ischemia are not well characterized. Hence, rapid assay methods for these enzymes would facilitate detailed time course studies of their activities in postischemic myocardium. We modified a single ion-exchange column chromatographic method using DEAE-Sephadex to determine the products of incubation of 5'-NT, AK, APRT and HPRT with their respective substrates. The uniformity of the final product measurement procedure for all assays permits the activities of the four enzymes to be rapidly determined in a single tissue sample and facilitates the study of a large number of samples. This technique should also be useful for enzymes of the pyrimidine metabolic pathway.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0378-4347(97)00577-xDOI Listing

Publication Analysis

Top Keywords

ion-exchange column
8
column chromatographic
8
chromatographic method
8
purine metabolic
8
metabolic pathway
8
activity enzymes
8
phosphoribosyl transferase
8
enzymes
7
method assaying
4
assaying purine
4

Similar Publications

Retention mechanism in slalom chromatography: Perspectives on the characterization of large DNA and RNA biopolymers in cell and gene therapy.

J Chromatogr A

January 2025

Waters Corporation, Instrument/Core Research/Fundamental, Milford, MA, 01757, USA. Electronic address:

Significant progress has been made in the last two decades in producing small (<2μm), high-purity, and low-adsorption particles, columns and system hardware, for ultra-high pressure liquid chromatography (UHPLC). Simultaneously, the recent rapid expansion of cell and gene therapies for treating diseases necessitates novel analytical technologies for analyzing large (>2 kbp) plasmid double-stranded (ds) DNA (which encodes for the in vitro transcription (IVT) of single-stranded (ss) mRNA therapeutics) and dsRNAs (related to IVT production impurities) biopolymers. In this context, slalom chromatography (SC), a retention mode co-discovered in 1988, is being revitalized using the most advanced column technologies for improved determination of the critical quality attributes (CQAs) of such new therapeutics.

View Article and Find Full Text PDF

Eurema mandarina is a pierid butterfly that primarily feeds on plants in the family Fabaceae. In mainland Japan, adult females preferentially lay eggs on Albizia julibrissin and Lespedeza cuneata. In the field, females may oviposit on non-fabaceous plants, although rarely.

View Article and Find Full Text PDF

Platforms have long been implemented for downstream process development of monoclonal antibodies (mAbs) to streamline development and reduce timelines. These platforms are also increasingly being used for other complex biologics modalities. While development has traditionally been conducted at the lab bench scale in a sequential manner, automated miniaturized and parallelized approaches like RoboColumns and resin plates have also been implemented for chromatographic screening.

View Article and Find Full Text PDF

Background: Per- and polyfluoroalkyl substances (PFAS) comprise thousands of fluorinated chemicals. They are of growing concern because many PFAS compounds are persistent and toxic. Food contact materials (FCM) containing PFAS pose multiple exposure pathways to humans, prompting twelve states to enact laws banning FCM with PFAS levels exceeding 100 ppm of TOF.

View Article and Find Full Text PDF

Ion exchange chromatography of biotherapeutics: Fundamental principles and advanced approaches.

J Chromatogr A

February 2025

School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland. Electronic address:

Ion exchange chromatography (IEX) is an important analytical technique for the characterization of biotechnology-derived products, such as monoclonal antibodies (mAbs) and more recently, cell and gene therapy products such as messenger ribonucleic acid (mRNA) and adeno-associated viruses (AAVs). This review paper first outlines the basic principles and separation mechanisms of IEX for charge variant separation of biotherapeutics, and examines the different elution modes based on salt or pH gradients. It then highlights several recent trends when applying IEX for the characterization of biotechnology-derived products, including: i) the effective use of pH gradients, ii) the improvement of selectivity by using organic solvents in the mobile phase, multi-step gradients, or by combining ion pairing and ion exchange, and iii) the increase in analytical throughput using ultra-short columns or automated screening of conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!