Purpose: To compare contrast sensitivity (CS) after implantation of a diffractive bifocal intraocular lens (IOL) and a monofocal IOL of similar design.

Setting: Seven European centers.

Methods: In this randomized, prospective study, CS was tested 5 months after cataract and IOL implantation surgery in 115 patients with a diffractive bifocal IOL and 106 patients with a monofocal IOL. It was also tested in a subgroup of 38 patients who had bilateral implantation of a diffractive bifocal IOL. Contrast sensitivity was tested using the Vision Contrast Test System (VCTS).

Results: In patients with a best corrected visual acuity (BCVA) of 1.0 or better, the CS at all spatial frequencies (1.5 to 18 cycles/degree), both at distance and near, was slightly lower in the bifocal IOL group than in the monofocal group. Mean values were within the normal range. In patients with a BCVA of less than 1.0, the CS was lower and the difference between the bifocal and monofocal groups was less. In patients with bilateral bifocal IOLs, CS was better when tested bilaterally than when testing the better eye alone. Pupil size affected the results to a small degree. Contrast sensitivity appeared to improve over time after implantation of a diffractive bifocal IOL.

Conclusions: In patients with cataract and no other eye pathology, the diffractive bifocal IOL with slightly reduce the CS at all spatial frequencies. In those with reduced visual acuity after cataract surgery, CS will be reduced accordingly. In this situation, the reduction from the diffractive bifocal optic would be minor.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(98)80260-5DOI Listing

Publication Analysis

Top Keywords

diffractive bifocal
28
contrast sensitivity
16
implantation diffractive
16
bifocal iol
16
bifocal
10
sensitivity implantation
8
bifocal monofocal
8
iol
8
monofocal iol
8
patients bilateral
8

Similar Publications

This study investigates whether a diffractive presbyopia-correcting multifocal intraocular lens disrupts the favorable interaction between chromatic and monochromatic aberrations in the eye. This is analyzed not only for distant objects but also for closer viewing distances, where the lens utilizes different diffraction orders depending on its design. We consider diffractive designs based on the zero-diffraction order for far vision and the first diffraction order for near vision (i.

View Article and Find Full Text PDF

In this work, we design and implement a new bifocal diffractive spiral lens within an optical tweezers system. The proposed diffractive optical element coined Kolokaski Kinoform Spiral Lens (KKSL), generates twin optical vortices along the propagation direction. The axial positions, as well as the diameters of the generated vortex beams, are correlated with the Kolakoski aperiodic sequence introduced in the design of the diffractive lens.

View Article and Find Full Text PDF

This study compares the optical quality of zonal refractive multifocal and diffractive bifocal intraocular lenses (IOLs) and visual outcomes after implantation in 93 patients(93 eyes) with cataracts and high myopia. A retrospective analysis was conducted to measure visual acuity at far, intermediate, and near distances, defocus curves, wavefront aberrations, modulation transfer function (MTF), a Quality of Vision questionnaire (QoV) and visual quality self-evaluation were examined at 3 months. The results demonstrated the ZMB group showed better uncorrected near visual acuity (P < 0.

View Article and Find Full Text PDF

In this work, we present a new family of Zone Plates (ZPs) designed using the self-generating Kolakoski sequence. The focusing and imaging properties of these aperiodic diffractive lenses coined Kolakoski Zone Plates (KZPs) are extensively studied. It is shown that under monochromatic plane-wave illumination, a KZP produces two main foci of the same intensity along the axial axis.

View Article and Find Full Text PDF

Retinal image quality for multifocal lenses with on- and off-axis annular zones.

Biomed Opt Express

June 2024

Division of Neurobiology, University of California, Berkeley, CA 94720-3200, USA.

Multi-focal intra-ocular or contact lenses, intended to increase depth of focus, conventionally have annular zones of additional refractive power, generating wavefront rings of coaxial spherical surfaces. It is, however, possible to influence depth of focus by changing not only the curvature of the wavefront, refractive power, in the annulus, but also the tilt, circularly symmetrical linear radial deviation imposed on the spherical wavefront. Employing the example of a single annulus bifocal, retinal image light distributions in the two regimes are calculated, using standard diffraction theory.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!