The Monte Carlo computer code MCNP (version 4A) has been used to develop a personal computer-based model of the Swansea in vivo neutron activation analysis (IVNAA) system. The model included specification of the neutron source (252Cf), collimators, reflectors and shielding. The MCNP model was 'benchmarked' against fast neutron and thermal neutron fluence data obtained experimentally from the IVNAA system. The Swansea system allows two irradiation geometries using 'short' and 'long' collimators, which provide alternative dose rates for IVNAA. The data presented here relate to the short collimator, although results of similar accuracy were obtained using the long collimator. The fast neutron fluence was measured in air at a series of depths inside the collimator. The measurements agreed with the MCNP simulation within the statistical uncertainty (5-10%) of the calculations. The thermal neutron fluence was measured and calculated inside the cuboidal water phantom. The depth of maximum thermal fluence was 3.2 cm (measured) and 3.0 cm (calculated). The width of the 50% thermal fluence level across the phantom at its mid-depth was found to be the same by both MCNP and experiment. This benchmarking exercise has given us a high degree of confidence in MCNP as a tool for the design of IVNAA systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0969-8043(97)00185-1 | DOI Listing |
iScience
January 2025
Department of Physics, University of California, Merced, Merced, CA, USA.
Metal halide perovskite (MHP) solar cells are promising aerospace power sources given their potential as inexpensive, lightweight, and resilient solar electricity generators. Herein, the intrinsic radiation tolerance of unencapsulated methylammonium lead iodide/chloride (CHNHPbICl) films was isolated. Spatially resolved photoluminescence (PL) spectroscopy and confocal microscopy revealed the fundamental defect physics through optical changes as films were irradiated with 4.
View Article and Find Full Text PDFAppl Radiat Isot
March 2025
Particle Radiation Oncology Research Center, Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2-Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan.
Recent decades have seen the development of accelerator neutron sources suitable for installation in a hospital setting. Numerous challenges have been faced and solved to deliver technology which continues to transform the field of BNCT. This paper begins by briefly reviewing the technologies which are currently, or soon will be, in clinical use.
View Article and Find Full Text PDFAstrobiology
January 2025
Institute of Environmental System Biology, Dalian Maritime University, Dalian, China.
The Space Radiobiological Exposure Facility (SREF) is a general experimental facility at the China Space Station for scientific research in the fields of space radiation protection, space radiation biology, biotechnology, and the origin of life. The facility provides an environment with controllable temperatures for experiments with organic molecules and model organisms such as small animals, plant seeds, and microorganisms. The cultivation of small animals can be achieved in the facility with the use of microfluidic chips and images and videos of such experiments can be captured by microscopy.
View Article and Find Full Text PDFPhys Med
January 2025
Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, Australia. Electronic address:
Rev Sci Instrum
December 2024
Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
As neutron yields increase at fusion facilities, a universal symptom the community must deal with is MeV neutron-induced backgrounds in cables running to diagnostics. On the first Gain >1 plasmas in the world, the National Ignition Facility (NIF) neutron time-of-flight (nToF) diagnostic registered significant cable backgrounds that compromised key performance measurements. The South Pole nToF is uniquely located inside the NIF Target Bay shield walls, ∼18 m from the fusion source, and consequently has long coaxial cable runs (>20 m) that see significant neutron fluence.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!