Background: On the basis of a previous experience in a chronic sheep model in which partial mitral allografts remained viable and properly functioning 12 months after operation, we assessed the results obtained by replacing the tricuspid valve with fresh antibiotic-preserved mitral allografts.
Methods: Twenty 3-month-old sheep with a mean weight of 23.7 +/- 2.3 kg underwent cardiopulmonary bypass and had a fresh antibiotic-preserved mitral allograft implanted in the tricuspid position with the heart beating under normothermic conditions. The tricuspid valve apparatus was not excised. After a mean follow-up of 13.2 months, the allograft was evaluated by gross inspection and light and electron microscopy.
Results: Nine sheep died of technical causes within the first week after operation and 2 at 4 and 6 months of infective endocarditis of the allograft. The hemodynamic study before heart explantation revealed residual tricuspid incompetence in 3 of the 9 survivors. Macroscopic examination showed flexible valves with no signs of structural deterioration, calcification, or thrombosis. Under light and scanning electron microscopic examination, allografts were almost completely denuded of endothelial cells and showed loosely arranged connective tissue with scarce signs of inflammatory reaction. Despite these findings, allografts were free from major structural damage.
Conclusions: The mitral homograft could be an alternative to replacement of the tricuspid valve with a bioprosthesis or a mechanical prosthesis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0003-4975(98)00185-4 | DOI Listing |
JACC Adv
January 2025
Department of General and Interventional Cardiology, Heart and Diabetes Center North Rhine-Westphalia, Ruhr University Bochum, Bad Oeynhausen, Germany. Electronic address:
Background: Patients with severe tricuspid regurgitation (TR) typically present with heterogeneity in the extent of cardiac dysfunction and extra-cardiac comorbidities, which play a decisive role for survival after transcatheter tricuspid valve intervention (TTVI).
Objectives: This aim of this study was to create a survival tree-based model to determine the cardiac and extra-cardiac features associated with 2-year survival after TTVI.
Methods: The study included 918 patients (derivation set, n = 631; validation set, n = 287) undergoing TTVI for severe TR.
Ultrasound J
January 2025
Pediatric Emergency Medicine, Yale University School of Medicine, 100 York Street, Suite 1F, New Haven, CT, 06511, USA.
E-point septal separation (EPSS) and tricuspid annular plane systolic excursion (TAPSE) are M-mode measures of left and right ventricular systolic function, with limited pediatric point-of-care ultrasound (POCUS) research. We conducted a cross-sectional study in a pediatric emergency department, enrolling 12-17-year-olds without cardiopulmonary complaints. Exclusion criteria included abnormal vital signs, fever, altered mental status, or psychiatric illness.
View Article and Find Full Text PDFJACC Cardiovasc Interv
January 2025
Structural Heart Program, St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada. Electronic address:
Zhonghua Er Ke Za Zhi
January 2025
Heart Center, Women and Children's Hospital, Qingdao University, Qingdao266034, China.
To evaluate the clinical efficacy of percutaneous balloon pulmonary valvuloplasty (PBPV) via antegrade venous-arterial loop in neonates with critical pulmonary stenosis with intact ventricular septum (CPS-IVS). A retrospective case review was conducted. Fifteen neonates with CPS-IVS who underwent PBPV via antegrade venous-arterial loop at the Women and Children's Hospital, Qingdao University between September 2020 and September 2023 were included.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Background: Data supporting the use of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) is limited compared to tricuspid aortic valve (TAV) anatomy, as the BAV anatomy poses unique challenges to prosthesis expansion and symmetric deployment.
Aims: We aim to compare the acute recoil and asymmetry of the SAPIEN-3 valve between BAV and TAV anatomies and their impact on procedural outcomes.
Methods: We conducted a single-center study of patients who underwent TAVR with the SAPIEN-3 valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!