Objectives: To evaluate magnetic resonance imaging (MRI) with gadolinium-based contrast medium-enhanced MR angiography (MRA) for the follow-up of endoluminally treated abdominal aortic aneurysms.

Design: MRI/MRA, angiography and computed tomography (CT) were performed 1 month after endoluminal stent-graft placement. MRI/MRA was repeated at 6 and 12 months and angiography and CT were added to confirm unexpected findings.

Materials: Fifteen male patients with endoluminally treated abdominal aortic aneurysms.

Methods: MRI with MRA, spiral CT with transverse images and angiography were performed.

Results: MRI/MRA demonstrated changes of stent-graft morphology, aortic neck- and aneurysmal diameter, stent-graft blood flow, stent-graft leakage, blood flow in lumbar arteries, intra-aneurysmal thrombus, periaortic inflammation and vertebral body infarction. For most of these features MRI/MRA provided more information than angiography and/or CT. MRI was the only method demonstrating thrombus reorganisation and vertebral body infarction.

Conclusions: MRI with MRA provides the relevant information needed for follow-up of endoluminally treated abdominal aortic aneurysms (AAA). This may be the method of choice because of its use of contrast media with very low nephrotoxicity, lack of ionising radiation and non-invasiveness.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1078-5884(98)80178-0DOI Listing

Publication Analysis

Top Keywords

endoluminally treated
16
treated abdominal
16
abdominal aortic
16
magnetic resonance
8
resonance imaging
8
aortic aneurysms
8
follow-up endoluminally
8
mri mra
8
blood flow
8
vertebral body
8

Similar Publications

Transcatheter Pulmonary Flow Restrictors as a Palliative Bridge to Heart Transplant.

Pediatr Transplant

February 2025

Division of Pediatric Cardiology, Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Background: In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding.

Case Presentation: A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%.

View Article and Find Full Text PDF

Rationale: Aortoesophageal fistula (AEF) is an exceedingly rare yet critically life-threatening condition, with mortality rates nearing 100% if not addressed promptly. AEF often develops in the context of thoracic aortic aneurysms, esophageal malignancies, or as a complication of foreign body ingestion and prior thoracic aortic surgeries. This study reports an exceptionally severe and clinically rare case of AEF associated with a pseudaneurysm induced by esophageal stenting.

View Article and Find Full Text PDF

Introduction: Congenital diaphragmatic hernia (CDH) in the preterm population is increasingly common in the current era of fetal endoluminal tracheal occlusion (FETO) therapy. There remains a lack of clinical guidance for clinicians and surgeons regarding optimal management strategies for such infants. We aimed to describe our experience in managing preterm CDH in a single quaternary neonatal intensive care unit (NICU).

View Article and Find Full Text PDF

The feasibility of the deep hypothermal cryotherapy plus immune checkpoint inhibitor for treatment of severe malignant central airway obstruction.

Chin Clin Oncol

December 2024

Department of Pulmonary and Critical Care Medicine, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, China.

Background: The recurrence shortly after interventional therapy poses a great challenge in managing malignant central airway obstruction (MCAO). While cryotherapy has shown potential benefits when combined with immunotherapy in lung cancer, its effectiveness for improving local control of malignant central airway tumors is not well understood. This study aims to evaluate the clinical efficacy and safety of combining these strategies.

View Article and Find Full Text PDF

3D printing in palliative medicine: systematic review.

BMJ Support Palliat Care

December 2024

Health Research Institute, School of Design, and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland

Background: Three-dimensional printing (3DP) enables the production of highly customised, cost-efficient devices in a relatively short time, which can be particularly valuable to clinicians treating patients with palliative care intent who are in need of timely and effective solutions in the management of their patients' specific needs, including the relief of distressing symptoms.

Method: Four online databases were searched for articles published by December 2020 that described studies using 3DP in palliative care. The fields of application, and the relevant clinical and technological data were extracted and analysed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!