The PFA-100 system is a platelet function analyzer designed to measure platelet-related primary hemostasis. The instrument uses two disposable cartridges: a collagen/epinephrine (CEPI) and a collagen/ADP (CADP) cartridge. Previous experience has shown that CEPI cartridges detect qualitative platelet defects, including acetylsalicylic acid (ASA)-induced abnormalities, while CADP cartridges detect only thrombocytopathies and not ASA use. In this seven-center trial, 206 healthy subjects and 176 persons with various platelet-related defects, including 127 ASA users, were studied. The platelet function status was determined by a platelet function test panel. Comparisons were made as to how well the defects were identified by the PFA-100 system and by platelet aggregometry. The reference intervals for both cartridges, testing the 206 healthy subjects, were similar to values described in smaller studies in the literature [mean closure time (CT) 132 s for CEPI and 93 s for CADP]. The use of different lot numbers of cartridges or duplicate versus singleton testing revealed no differences. Compared with the platelet function status, the PFA-100 system had a clinical sensitivity of 94.9% and a specificity of 88.8%. For aggregometry, a sensitivity of 94.3% and a specificity of 88.3% were obtained. These values are based on all 382 specimens. A separate analysis of sensitivity by type of platelet defect, ASA use versus congenital thrombocytopathies, revealed for the PFA-100 system a 94.5% sensitivity in identifying ASA users and a 95.9% sensitivity in identifying the other defects. For aggregometry, the values were 100% for ASA users and 79.6% for congenital defects. Analysis of concordance between the PFA-100 system and aggregometry revealed no difference in clinical sensitivity and specificity between the systems (p > 0.9999). The overall agreement was 87.5%, with a Kappa index of 0.751. The two tests are thus equivalent in their ability to identify normal and abnormal platelet defects. Testing 126 subjects who took 325 mg ASA revealed that the PFA-100 system (CEPI) was able to detect 71.7% of ASA-induced defects with a positive predictive value of 97.8%. The overall clinical accuracy of the system, calculated from the area under the ROC curve, was 0.977. The data suggest that the PFA-100 system is highly accurate in discriminating normal from abnormal platelet function. The ease of operation of the instrument makes it a useful tool to use in screening patients for platelet-related hemostasis defects.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2007-995840DOI Listing

Publication Analysis

Top Keywords

pfa-100 system
32
platelet function
20
asa users
12
platelet
10
pfa-100
8
system
8
system platelet
8
cartridges detect
8
defects
8
platelet defects
8

Similar Publications

Background: This study investigated whether point-of-care platelet function measurements could predict favorable outcomes in patients with acute ischemic stroke (AIS). Antiplatelet agents, such as aspirin, are known to reduce the risk of recurrent stroke by 20-30%. However, identifying nonresponders to therapy remains a clinical challenge.

View Article and Find Full Text PDF

Evaluation of coagulation and platelet activation state and function in heartworm-infected dogs.

Vet Clin Pathol

June 2024

Department of Small Animal Medicine & Surgery, College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA.

Background: Enhanced platelet responses have been demonstrated in heartworm-infected (HWI) dogs; however, the cause and clinical implications of altered platelet function have not been fully elucidated.

Objective: This study evaluated platelet function in HWI dogs.

Methods: Anticoagulated whole blood collected from eight HWI and eight uninfected dogs was evaluated using turbidometric platelet aggregometry, a platelet function analyzer (PFA-100), a total thrombus analysis system (T-TAS), tissue factor-activated and tissue plasminogen activator modified thromboelastography (TF- and tPA-TEG), CBC, von Willebrand Factor activity, and fibrinogen concentrations.

View Article and Find Full Text PDF

Introduction: Use of anabolic-androgenic steroids (AAS) is associated with adverse cardiovascular (CV) effects, including potential prothrombotic effects. This study aimed to assess platelet activation and aggregation, coagulation, and fibrinolysis, in long-term AAS users compared to non-using strength-trained athletes.

Materials And Methods: Thirty-seven strength-trained men using AAS were compared to seventeen non-using professional strength-trained athletes at similar age (median 33 years).

View Article and Find Full Text PDF

This is a celebratory reprint of a historical paper published in STH in 1998. The original Abstract follows.The PFA-100 system is a platelet function analyzer designed to measure platelet-related primary hemostasis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!