There are only a few reported cases of a pacemaker lead migrating inadvertently into the left atrium or ventricle. An unusual complication of unremoved, unwanted pacemaker lead is presented. The free tip of the lead caused cerebral embolism after perforating the interatrial septum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1998.tb00111.x | DOI Listing |
Front Cardiovasc Med
January 2025
Department of Cardiology, University of Health Sciences, Erzurum Bolge Training and Research Hospital, Erzurum, Turkey.
Background: Our aim in this case was to remove the defective ventricular lead and the ruptured coronary sinus lead.
Methods: Entering through the right femoral vein and removing the coronary sinus lead with a pigtail catheter.
Results: In our attempt to extract the coronary sinus lead, it fractured.
Cardiol Young
January 2025
Children's Heart Center Nevada, Las Vegas, NV, USA.
A 69-year-old man had an abnormal intracardiac course of a pacemaker lead. CT angiography demonstrated a window between the right upper pulmonary vein and the superior caval vein. The window was treated with covered stents in the superior caval vein, which was complicated by a chronic pericardial effusion that was treated with a pericardial window 6 months later.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFVet Sci
January 2025
Department of Clinics, Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 700490 Iasi, Romania.
A 3-year-old spayed male mixed-breed Labrador presented to the Emergency and Critical Care Unit with lethargy, loss of appetite, vomiting, a recent history of presyncopal episodes, and severe exercise intolerance. On admission, the patient had bradycardia, low blood pressure, and mild abdominal pain. Serum biochemistry information revealed severe hyperkalemia, hyponatremia, hypoglycemia, and mildly increased liver and kidney parameters.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Department of Hematology and Oncology, Shenzhen Children's Hospital of China Medical University, Shenzhen, 518038, China.
Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.
Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.