Background: Fluoroscopy, cost, and patient transport contribute to difficulties occasionally associated with the placement of vena caval filters. Follow-up data in the literature document the use of duplex ultrasonography in visualizing the filter and determining caval patency. Filter placement at the bedside or in the vascular laboratory with duplex ultrasonography may simplify this common procedure. We have attempted to define the feasibility of this method.
Methods: Patients referred to the vascular surgery service for vena caval interruption were evaluated for ability to visualize the renal veins and inferior vena cava. Location of renal veins, maximum diameter of the vena cava, and presence or absence of thrombus were documented. If visualization was adequate, placement was performed at the bedside for patients in intensive care or in the vascular laboratory for nonmonitored patients. The initial 10 patients and subsequent patients in whom there was a question of adequate deployment underwent completion abdominal roentgenography. Patient follow-up was difficult. Duplex ultrasonography was used to assess migration, thrombus adherent to the filter, and vena caval patency. Patients in whom filter placement was prophylactic were given anticoagulants at the discretion of the primary physician. Inadequate visualization or vena caval size greater than 28 mm prompted fluoroscopic placement of the vena caval filter, because only Greenfield titanium filters were used in the study.
Results: Twenty-nine patients were referred for vena caval interruption. Inadequate visualization occurred in four obese patients, and filters were placed by fluoroscopy. There were no vena caval measurements greater than 24 mm. Twenty-five filters were placed without technical difficulty. One filter tilted into the right renal vein, requiring a suprarenal filter placed by fluoroscopy. Patient retrieval for follow-up has been difficult, but by ultrasonography there has been one vena caval thrombosis and no major filter migration. There have been no reported pulmonary emboli other than the one patient with initial tilt of the filter.
Conclusions: Placement of vena caval filters is feasible with duplex ultrasonography. Visualization is the only limiting condition to placement and occurs rarely. Reducing the need for fluoroscopy, lowering costs, and not needing to transport the critically ill patient support the use of this system. Intravascular ultrasonography in selected patients may eliminate the need for fluoroscopic placement of vena caval filters.
Download full-text PDF |
Source |
---|
Eur J Med Res
January 2025
Medical Big Data Research Center, Medical Innovation Research Division, Chinese PLA General Hospital, 28 Fuxing RD., Beijing, 100853, China.
Background: Chronic kidney disease (CKD) carries the highest population attributable risk for mortality among all comorbidities in chronic heart failure (CHF). No studies about the association between inferior vena cava (IVC) diameter and all-cause mortality in patients with the comorbidity of CKD and CHF has been published.
Methods: In this retrospective cohort study, a total of 1327 patients with CHF and CKD were included.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, City of Health and Science (Città della Salute e della Scienza) and Department of Surgical Sciences, University of Turin, Turin, Italy.
Current cardiac surgery has evolved to include hybrid and minimally invasive settings. In parallel, less invasive techniques have been extended to complex clinical scenarios and may prove even more beneficial in higher-risk patients. However, comorbidities and challenging anatomy still represent limitations to widespread application of this philosophy.
View Article and Find Full Text PDFBMC Emerg Med
January 2025
Department of Emergency Medicine, Recep Tayyip Erdoğan University Training and Research Hospital, Rize, 53020, Turkey.
Background: The incidence of contrast-induced acute kidney injury (CI-AKI) in the general population ranges from 0.6 to 2.3%, whereas for specific high-risk patients, the incidence can reach more than 30-40%.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand.
The formula-based estimation of the right internal jugular venous (IJV) catheterization depth can be inaccurate when using ultrasound guidance. External landmark-based and radiological landmark-based methods have been proposed as alternatives to estimate the insertion depth. This study aimed to evaluate these methods using transesophageal echocardiography (TEE)-guided insertion depth as the reference.
View Article and Find Full Text PDFNagoya J Med Sci
November 2024
School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
Intracardiac migration of inferior vena cava (IVC) filter or stent is a rare but potentially fatal complication of endovascular venous device placement. There is no consensus whether migrated stents should be surgically removed by open cardiac surgery or retrieved by the percutaneous endovascular route and whether an intervention should be performed immediately or expectantly. Herein, we report a 39-year-old female who received emergent left lobe living donor liver transplantation (LDLT) owing to posthepatectomy liver failure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!