Ultrastructural and electron diffraction of the bone-ceramic interfacial zone in coral and biphasic CaP implants.

Calcif Tissue Int

Laboratoire de recherche sur les matériaux d'intérêt biologique, Université de Nantes, Nantes, France.

Published: May 1998

We investigated the influence of natural coral implants used as a bone substitute on the quality of bone ingrowth in rabbits 2, 3, and 6 weeks after implantation. Explants were characterized by transmission electron microscopy and electron diffraction. Bone ingrowth has been previously demonstrated by light microscopy, however, few have been performed in electron microscopy to compare mineralized tissue ingrowth in coral implants which occurs at the expense of calcium carbonate to that of calcium phosphate (CaP) implants. The interface between coral aragonite and mineralized tissue or bone was abrupt, with no invasion of the aragonite structure by newly formed crystals, as occurs in micropores when biphasic CaP (BCP) ceramics were used. The restoring process appears to be different from that induced by BCP implants. Precipitation of needle-like apatite crystals on the CaCO3 implant surface was not observed. Instead, apatitic smooth-shaped crystals formed in aggregates. The coral dissolution process does not release phosphate and so precipitation of apatite does not occur in the micropores of the coral implant, thereby limiting the formation of an apatite layer and hence bone bonding to the outer surface of the implant. In addition, on the outer surface of the implant, close to bone and a phosphorus source, the CaP crystals that do form are in aggregates presumably due to the carbonate and mismatch between the aragonite and the apatite. This seems to result in a delayed bone attachment or weaker bone bonding than CaP implants which encourage an epitaxial biological crystal deposition.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s002239900456DOI Listing

Publication Analysis

Top Keywords

cap implants
12
electron diffraction
8
biphasic cap
8
coral implants
8
bone
8
bone ingrowth
8
electron microscopy
8
mineralized tissue
8
bone bonding
8
outer surface
8

Similar Publications

Introduction: Chronic inflammation leading to implant failure present major challenges in orthopedics, dentistry, and reconstructive surgery. Titanium alloys, while widely used, often provoke inflammatory complications. Zinc-doped calcium phosphate (CaP) coatings offer potential to enhance implant integration by improving corrosion resistance, bioactivity, and immunocompatibility.

View Article and Find Full Text PDF

Following implantation, infections, inflammatory reactions, corrosion, mismatches in the elastic modulus, stress shielding and excessive wear are the most frequent reasons for orthopedic implant failure. Natural polymer-based coatings showed especially good results in achieving better cell attachment, growth and tissue-implant integration, and it was found that the inclusions of nanosized fillers in the coating structure improves biomineralization and consequently implant osseointegration, as the nanoparticles represent calcium phosphate nucleation centers and lead to the deposition of highly organized hydroxyapatite crystallites on the implant surface. In this study, magnetic nanoparticles synthesized by the co-precipitation method were used for the preparation of cellulose acetate composite coatings through the phase-inversion method.

View Article and Find Full Text PDF

Calcium Phosphate (CaP) Composite Nanostructures on Polycaprolactone (PCL): Synergistic Effects on Antibacterial Activity and Osteoblast Behavior.

Polymers (Basel)

January 2025

Division of Mechanical Engineering, College of Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Jeonbuk, Republic of Korea.

Bone tissue engineering aims to develop biomaterials that are capable of effectively repairing and regenerating damaged bone tissue. Among the various polymers used in this field, polycaprolactone (PCL) is one of the most widely utilized. As a biocompatible polymer, PCL is easy to fabricate, cost-effective, and offers consistent quality control, making it a popular choice for biomedical applications.

View Article and Find Full Text PDF

Periprosthetic joint infections occur in 1-2% of all patients undergoing prosthetic joint surgeries. Although strong efforts have been made to reduce infection rates, conventional therapies like one- or two-stage revisions have failed to lower the infection rates. Cold atmospheric plasma (CAP) has shown promising results in reducing bacterial loads on surfaces.

View Article and Find Full Text PDF

Chronic endometritis (CE) is a persistent inflammatory condition of the endometrium characterized by abnormal infiltration of plasma cells into the endometrial stroma. Frequently associated with repeated implantation failure, recurrent pregnancy loss, and infertility, CE significantly impacts women's health, contributing to conditions such as abnormal uterine bleeding and endometriosis. Treatment typically involves antibiotic therapy; however, the efficacy of these treatments is increasingly compromised by the rise of antimicrobial resistance (AMR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!