A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aneurysm of sinus of Valsalva dissecting into interventricular septum. | LitMetric

Background: Dissection of interventricular septum by aneurysm of the sinus of Valsalva is extremely rare. We present our experience with the management of 10 patients with this condition.

Methods: Ten patients with aneurysm of the sinus of Valsalva dissecting into the interventricular septum were managed at All India Institute of Medical Sciences, New Delhi, between May 1987 and September 1996. Conduction abnormalities and aortic insufficiency dominated the clinical picture. Eight patients underwent surgical repair. Two patients refused operation, and only permanent pacemaker implantation was done for complete heart block in both these patients.

Results: There was no hospital mortality. Follow-up ranged from 1 to 9 years. There was one late death due to carcinoma of the larynx, and 1 patient required reoperation for persistent aortic insufficiency. All other patients who underwent operation are in New York Heart Association functional class I.

Conclusions: We recommend surgical repair of this condition to deal with aortic regurgitation and to avoid the potential risk of rupture, thromboembolism, and infective endocarditis. However, surgical repair offers no guarantee against arrhythmias and conduction abnormalities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-4975(97)01432-xDOI Listing

Publication Analysis

Top Keywords

aneurysm sinus
12
sinus valsalva
12
interventricular septum
12
surgical repair
12
valsalva dissecting
8
dissecting interventricular
8
conduction abnormalities
8
aortic insufficiency
8
patients underwent
8
patients
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!