A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait.

IEEE Trans Biomed Eng

Dipartimento di Elettronica, Politecnico di Torino, Italy.

Published: March 1998

The aim of this work is to present an original double-threshold detector of muscle activation, specifically developed for gait analysis. This detector operates on the raw myoelectric signal and, hence, it does not require any envelope detection. Its performances are fixed by the values of three parameters, namely, false-alarm probability (Pfa), detection probability, and time resolution. Double-threshold detectors are preferable to single-threshold ones because, for a fixed value of the Pfa, they yield higher detection probability; furthermore, they allow the user to select the couple false alarm-detection probability with a higher degree of freedom, thus, adapting the performances of the detector to the characteristics of the myoelectric signal of interest and of the experimental situation. In this paper, first we derive the detection algorithm and describe different strategies for selecting its parameters, then we present the performances of the proposed procedure evaluated by means of computer simulations, and finally we report an example of application to myoelectric signals recorded during gait. The characterization of the proposed double-threshold detector demonstrates that, in most practical situations, the bias of the estimates of the on-off transitions is smaller than 10 ms, the standard deviation may be kept lower than 15 ms, and the percentage of erroneous patterns is below 5%. These results show that this detection approach is satisfactory in research applications as well as in the clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1109/10.661154DOI Listing

Publication Analysis

Top Keywords

myoelectric signal
12
muscle activation
8
double-threshold detector
8
detection probability
8
detection
5
statistical method
4
method measurement
4
measurement muscle
4
activation intervals
4
intervals surface
4

Similar Publications

Plug-and-play myoelectric control via a self-calibrating random forest common model.

J Neural Eng

January 2025

School of Informatics, The University of Edinburgh, 10 Chricton Street, Edinburgh, EH8 9LE, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.

Objective: Electromyographic (EMG) signals show large variabilities over time due to factors such as electrode shifting, user behaviour variations, etc., substantially degrading the performance of myoelectric control models in long-term use. Previously one-time model calibration was usually required each time before usage.

View Article and Find Full Text PDF

3D printable and myoelectrically sensitive hydrogel for smart prosthetic hand control.

Microsyst Nanoeng

January 2025

Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou, 511442, P. R. China.

Surface electromyogram (sEMG) serves as a means to discern human movement intentions, achieved by applying epidermal electrodes to specific body regions. However, it is difficult to obtain high-fidelity sEMG recordings in areas with intricate curved surfaces, such as the body, because regular sEMG electrodes have stiff structures. In this study, we developed myoelectrically sensitive hydrogels via 3D printing and integrated them into a stretchable, flexible, and high-density sEMG electrodes array.

View Article and Find Full Text PDF

Motion analysis for the evaluation of dynamic spasticity during walking: A systematic scoping review.

Mult Scler Relat Disord

January 2025

Department of Neurology and Neurological Rehabilitation, Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai 201619, China. Electronic address:

Background: Three-dimensional (3D) gait analysis has the potential to assess dynamic spasticity (DS). However, little is known about which parameters can be utilized for assessment.

Objective: To evaluate the application of 3D gait analysis in assessing DS during walking and to identify the most relevant parameters for clinical practice.

View Article and Find Full Text PDF

Myoelectric control has emerged as a promising approach for a wide range of applications, including controlling limb prosthetics, teleoperating robots and enabling immersive interactions in the Metaverse. However, the accuracy and robustness of myoelectric control systems are often affected by various factors, including muscle fatigue, perspiration, drifts in electrode positions and changes in arm position. The latter has received less attention despite its significant impact on signal quality and decoding accuracy.

View Article and Find Full Text PDF

Highly Responsive Robotic Prosthetic Hand Control Considering Electrodynamic Delay.

Sensors (Basel)

December 2024

Department of Robotics and Mechatronics, Tokyo Denki University, Tokyo 120-8551, Japan.

As robots become increasingly integrated into human society, the importance of human-machine interfaces continues to grow. This study proposes a faster and more accurate control system for myoelectric prostheses by considering the Electromechanical Delay (EMD), a key characteristic of Electromyography (EMG) signals. Previous studies have focused on systems designed for wrist movements without attempting implementation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!