Background: A previous study in 1987 showed that neonatal care facilities in major hospitals in the country were of a very poor standard. The present study was done to reassess their status.
Design: A survey.
Methods: A pretested structured questionnaire was sent to 48 centers in 1994-95. The responses were analyzed.
Results: A total of 37 centers returned the questionnaire duly filled. Of them, 22 belonged to the government sector, the rest 15 to the private sector. A nursery bed: nurse ratio of less than 1.0 was reported by only 4 centers. Majority of the centers cited inadequate nursing strength and frequent transferring out of nurses as a major problem. Twenty nine (78%) centers had ventilation facilities. Most of them had 1 or 2 ventilators. Blood gas facility was available with 29 centers and parenteral nutrition was undertaken at 20 (54%) centers. Resuscitation bag(s) were available at all the centers and incubators at all except one. In quantitative terms, the following equipment was available in satisfactory numbers: resuscitation bags, resuscitation bassinet, incubators/open care systems, vital sign monitors, infusion pumps and pulse oximeters in 78.3%, 43.2%, 72.9%, 56.7%, 64.8% and 43.5% centers, respectively. Indigenous products of the following categories were reasonably well accepted: resuscitation bags, resuscitation bassinets, incubators, open care systems and dextrometers.
Conclusion: The newborn care facilities, particularly the ventilation facilities, have improved in recent years. Almost 10 units were operating at or near level III standard of newborn care. Indigenous equipment of selected categories is replacing the imported equipment. However, most units continue to face problems of shortage of nursing personnel.
Download full-text PDF |
Source |
---|
Int J Clin Pharm
February 2025
Department of Pharmacy, CHU-UCL Namur, Av. Gaston Therasse 1, 5530, Yvoir, Belgium.
Background: Inappropriate use of intravenous (IV) fluids results in fluid overload, electrolyte disturbances, and increased costs.
Aim: To describe IV fluid prescribing and its appropriateness in hospitalised patients.
Method: A point prevalence study was conducted at two sites (academic and general) of a tertiary care hospital in Belgium.
Cureus
October 2024
Department of Anesthesiology, Uniformed Services University of the Health Sciences, Bethesda, USA.
J Spec Oper Med
October 2024
Department of Medicine.
Mil Med
August 2024
Resuscitation Science Center of Emphasis, Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
Introduction: Despite the significant need for mechanical ventilation in- and out-of-hospital, mechanical ventilators remain inaccessible in many instances because of cost or size constraints. Mechanical ventilation is especially critical in trauma scenarios, but the impractical size and weight of standard mechanical ventilators restrict first responders from carrying them in medical aid bags, leading to reliance on imprecise manual bag-mask ventilation. This is particularly important in combat-related injury, where airway compromise and respiratory failure are leading causes of preventable death, but medics are left without necessary mechanical ventilation.
View Article and Find Full Text PDFPLoS One
May 2024
Department of Physiotherapy, Faculty of Allied Health Sciences, University of Peradeniya, Peradeniya, Sri Lanka.
Introduction: Hyperinflation is a common procedure to clear secretion, increase lung compliance and enhance oxygenation in mechanically ventilated patients. Hyperinflation can be provided as manual hyperinflation (MHI) or ventilator hyperinflation (VHI), where outcomes depend upon the methods of application. Hence it is crucial to assess the application of techniques employed in Sri Lanka due to observed variations from recommended practices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!