We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
Download full-text PDF |
Source |
---|
Sci Rep
January 2025
Medical Oncology Department, Central University Hospital of Asturias, Oviedo, Spain.
Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.
View Article and Find Full Text PDFJSES Rev Rep Tech
February 2025
Clinique Claude Bernard, Unité de Chirurgie Orthopédique, Metz, France.
Background: The importance of the subscapularis for reverse total shoulder arthroplasty has been demonstrated, especially for internal rotation and stability. In a deltopectoral approach, a detachment of the subscapularis is performed (tenotomy, tuberosity peeling, or osteotomy), but the tendon is not always repairable at the end. When it is repaired, healing is obtained in only 40%-76% of the cases, with potential consequences for the outcomes.
View Article and Find Full Text PDFJ Clin Med
January 2025
Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
Transalveolar sinus floor elevation (TSFE) is a surgical technique for the placement of dental implants in patients with reduced height of the maxillary posterior alveolar bone. This study aims to demonstrate the clinical outcomes of TSFE using the minimal invasive sinus elevation (MISE) technique in partially and totally edentulous maxillary patients. This prospective clinical study followed STROBE guidelines.
View Article and Find Full Text PDFSurg Pract Sci
March 2024
Surgery Department, Hospital Pedro Hispano, R. de Dr. Eduardo Torres, Matosinhos, Senhora da Hora 4464-513, Portugal.
Background: Totally implantable venous central access devices (TIVADs) can be implanted by open surgery or by direct puncture in the subclavian (ScV), internal jugular (IJV) or cephalic (CephV) veins.
Methods: A retrospective study was conducted in 201 patients. Thirty-day follow-up data was analyzed to compare the outcomes of different techniques and evaluation of risk factors.
Materials (Basel)
January 2025
Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially and totally edentulous patients using a two-stage surgical technique and an early loading protocol (6-8 weeks).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!