Sonographic image density represents tissue echogenicity, or the acoustic nature of scanned tissue. It has the potential to distinguish normal from abnormal tissue. Humans are poor assessors of tissue echogenicity, yet their abilities have not been quantitatively compared to more objective methods. We compared the accuracy of image density differentiation by the human eye and by densitometry in the fetal liver model. A group of 60 observers was asked to compare the echogenicity of three pairs of images of a fetal liver. Twenty-three repeated the comparison several weeks later. Image density was measured by electro-optical densitometry. The two-tailed signed rank test was used to compare the observer's perceptions with the density values and the repeated observations with the original responses. The density of each fetal liver image in pair A was the same. Image B1 had a 12.3% lower density than image B2, and image C1 had a 6.3% greater density than image C2. Observers were accurate more often when comparing images with large density differences (pair B) than they were when comparing images with the same density (pair A) or with small density differences (pair C). Accuracy was not related to being medically qualified or from an obstetric or gynecological department. Intraobserver variation was not significant. We conclude that the human eye is extremely inaccurate at discerning differences in echogenicity when images have small or no differences in optical density. Densitometry is, therefore, indispensable for accurate image density assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1469-0705.1997.10050346.xDOI Listing

Publication Analysis

Top Keywords

image density
16
density
13
density differences
12
fetal liver
12
image
9
tissue echogenicity
8
human eye
8
density image
8
comparing images
8
differences pair
8

Similar Publications

: Caries or iatrogenic thermal trauma of the teeth have a significant impact on the dental pulp structure connected with stimulation of angiogenesis and lymphangiogenesis. Therefore, the aim of the study was to identify the difference in the rate of heat dissipation by vessels present in the dental pulp. : Freshly extracted healthy ( = 10) and carious ( = 14) molars and premolars were cut on a diamond saw and subjected to active thermographic examination and then subjected to lymphoscintigraphy and X-ray examination.

View Article and Find Full Text PDF

Background: The relationships between pectoralis muscle parameters and outcomes in patients with coronavirus disease 2019 (COVID-19) remain uncertain.

Methods: We systematically searched PubMed, Embase, Web of Science and the Cochrane Library from 1 January 2019 to 1 May 2024 to identify non-overlapping studies evaluating pectoralis muscle-associated index on chest CT scan with clinical outcome in COVID-19 patients. Random-effects and fixed-effects meta-analyses were performed, and heterogeneity between studies was quantified using the I2 statistic.

View Article and Find Full Text PDF

In Situ Analysis of Li Plating and Stripping Behaviors Under Dynamic Current Conditions for Realistic Application Scenarios.

Adv Sci (Weinh)

January 2025

State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology (HUST), Wuhan, 430074, China.

Lithium metal batteries are considered the holy grail for next-generation high-energy systems. However, lithium anode faces poor reversibility, unsatisfying cyclability and rate capability due to its uncontrollable plating/stripping behavior. While galvanostatic conditions are extensively studied, the behavior under more realistic application scenarios with variable inputs are less explored.

View Article and Find Full Text PDF

Wave-CAIPI Multiparameter MR Imaging in Neurology.

NMR Biomed

March 2025

Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.

In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.

View Article and Find Full Text PDF

Background/purpose: Inferior alveolar nerve (IAN) injury is the most serious complication associated with dental implant surgery, posing difficulties in treatment and potential for permanent disabilities. This study aimed to identify patient-related risk factors for IAN injury during implant placement and to investigate sensory disturbances depending on whether the implant was removed.

Materials And Methods: Twenty-eight patients with implant-related IAN injury were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!