Objective: The effects of prolonged arteriovenous carbon dioxide removal on hemodynamics during severe respiratory failure were evaluated in adult sheep with severe smoke inhalation injury.

Methods: Adult female sheep (n = 6,33.8 +/- 5.2 kg) were subjected to intratracheal cotton severe smoke insufflation to a mean carboxyhemoglobin level of 83% +/- 3%. Twenty-four hours after injury, a low-resistance 2.5 m2 membrane oxygenator was placed in a carotid-to-jugular pumpless arteriovenous shunt at unrestricted flow to allow complete carbon dioxide removal and reductions in ventilator support. Animals remained conscious, and heart rate, cardiac output, mean arterial pressure, and pulmonary arterial pressure were measured at baseline, after injury, and daily during support with the arteriovenous carbon dioxide removal circuit for 7 days.

Results: All animals survived the study period. Carbon dioxide removal ranged from 99.7 +/- 13.7 to 152.2 +/- 16.2 ml/min, and five (83%) of the six animals were successfully weaned from the ventilator before day 7. During full support with the arteriovenous carbon dioxide removal circuit, shunt flow ranged from 1.24 +/- 0.06 to 1.43 +/- 0.08 L/min and accounted for 20.1% +/- 1.4% to 25.9% +/- 2.4% of cardiac output. No statistically significant changes in heart rate, cardiac output, mean arterial pressure, or pulmonary artery pressure were demonstrated over the study course despite the extracorporeal shunt flow.

Conclusions: Arteriovenous carbon dioxide removal as a simplified means of extracorporeal gas exchange support is relatively safe without adverse hemodynamic effects or complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0022-5223(97)70026-6DOI Listing

Publication Analysis

Top Keywords

carbon dioxide
28
dioxide removal
28
arteriovenous carbon
20
cardiac output
12
arterial pressure
12
severe respiratory
8
respiratory failure
8
severe smoke
8
+/-
8
heart rate
8

Similar Publications

Generalized Hartree-Fock (GHF) is a long-established electronic structure method that can lower the energy (compared to spin-restricted variants) by breaking physical wave function symmetries, namely and . After an exposition of GHF theory, we assess the use of GHF trial wave functions in phaseless auxiliary field quantum Monte Carlo (ph-AFQMC-G) calculations of strongly correlated molecular systems including symmetrically stretched hydrogen rings, carbon dioxide, and dioxygen. Imaginary time propagation is able to restore symmetry and yields energies of comparable or better accuracy than CCSD(T) with unrestricted HF and GHF references, and consistently smooth dissociation curves─a remarkable result given the relative scalability of ph-AFQMC-G to larger system sizes.

View Article and Find Full Text PDF

Carbon dioxide injection through coronary vein puncture can greatly reduce complications from epicardial access. We reported a case of ventricular tachycardia that was successfully ablated by this procedure under ECMO support.

View Article and Find Full Text PDF

The strong influence of surface adsorbates on the morphology of a catalyst is exemplified by studying a silver surface with and without deposited zinc oxide nanoparticles upon exposure to reaction gases used for carbon dioxide hydrogenation. Ambient pressure X-ray photoelectron spectroscopy and scanning tunneling microscopy measurements indicate accumulation of carbon deposits on the catalyst surface at 200 °C. While oxygen-free carbon species observed on pure silver show a strong interaction and decorate the atomic steps on the catalyst surface, this decoration is not observed for the oxygen-containing species observed on the silver surface with additional zinc oxide nanoparticles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!