We measured the eye movements of three sisters with Niemann-Pick type C disease who had a selective defect of vertical saccades, which were slow and hypometric. Horizontal saccades, and horizontal and vertical pursuit and vestibular eye movements were similar to control subjects. The initial movement of oblique saccades was mainly horizontal and most of the vertical component occurred after the horizontal component ended; this resulted in strongly curved trajectories. After completion of the horizontal component of an oblique saccade, the eyes oscillated horizontally at 10-20 Hz until the vertical component ended. These findings are best explained by models that incorporate separate feedback loops for horizontal and vertical burst neurons, and in which the disease selectively affects vertical burst neurons.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0042-6989(96)00066-1 | DOI Listing |
Aesthet Surg J
January 2025
Department of Histology and Embryology, Gazi University, Ankara, Türkiye.
Background: There are several articles discussing the use of a hemostatic net to close dead spaces, but no in-vivo experimental studies have simultaneously examined the histology and tissue perfusion of these techniques.
Objectives: Our aim is to compare variations of the hemostatic net technique commonly used in current practice.
Methods: Two different hemostatic net suturing techniques and two times of suture removal were tested, with a control group for comparison.
BMC Oral Health
January 2025
Faculty of Dentistry Department of Oral and Maxillofacial Radiology, Ondokuz Mayıs University, Atakum/Samsun, Turkey.
Aim: This study aimed to evaluate the prevalence, location and diameters of Posterior superior alveolar artery (PSAA) and Infraorbital foramen (IOF) to find out whether there is any relationship between PSAA and IOF, and to predict their location relative to each other in surgical procedures by using cone beam computed tomography (CBCT).
Material And Method: Bilateral maxillary sinuses were analysed retrospectively in 170 patients with no missing teeth in the maxillary posterior region. The largest locations of PSAA and IOF in the maxillary sinus were determined and their size, shape, location in relation to the teeth and distances from anatomical points were evaluated.
Sci Rep
January 2025
China Institute of Water Resources and Hydropower Research, Beijing, 100038, China.
To alleviate water resource shortages and tensions and meet the water diversion needs of different river basins, buried (cross-dam) pipelines have become an essential component of water diversion projects. They are installed in levee projects in key river basins such as the Yellow River, Jingjiang River, and Beijiang River. Due to the complex engineering structure and multiple sources of vibration excitation, if vibrations propagate along the pipeline axis towards the surrounding levee, they could have an adverse impact on the stability and safe operation of the levee.
View Article and Find Full Text PDFNeurosci Res
January 2025
Division of Neuroanatomy, Department of Neuroscience, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, 755-8505, Japan; School of Human Care Studies, Nagoya University of Arts and Sciences, 57 Takenoyama, Iwasaki-cho, Nishin city, Aichi 470-0196, Japan. Electronic address:
Huntingtin-associated protein 1 (HAP1) is an essential constituent of the stigmoid body (STB) and is known as a neuroprotective interactor with causal agents for several neurodegenerative disorders, including huntingtin (HTT) in Huntington's disease. Previous in vitro studies showed that compared to normal HTT, STB/HAP1 exhibited a higher binding affinity for mutant HTT. However, the detailed in vivo relationships of STB/HAP1 with endogenous HTT have not been clarified yet.
View Article and Find Full Text PDFInt J Implant Dent
January 2025
Department of Neurosciences, School of Dentistry, University of Padua, Padua, Italy.
Objective: This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.
Materials And Methods: Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!