Rationale And Objectives: We compared adverse reactions and image quality for hysterosalpingography (HSG) performed with ionic (diatrizoate meglumine combined with iodipamide meglumine [DM + IM]) and nonionic (iohexol) contrast media.
Methods: We performed a study of 95 patients who had HSG and were randomly selected to receive DM + IM or iohexol. Patients reported episodes of abdominal pain and other adverse reactions immediately and 24 hr after the procedure and categorized severity of symptoms on a subjective scale. Two radiologists evaluated image quality for diagnosis.
Results: Prevalence of abdominal pain and other reactions both immediately and 24 hr after HSG was lower in patients who received iohexol than in patients who received DM + IM. Moderate or severe abdominal pain was significantly lower in the iohexol group than in the DM + IM group (p < .05). Visualization of the uterine cavity and ampullary rugae was judged excellent with both contrast media (87% with iohexol and 92% with DM + IM).
Conclusion: Iohexol and DM + IM are excellent contrast media for use during HSG; iohexol 300 may cause fewer episodes of more severe and prolonged abdominal pain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S1076-6332(05)80146-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!