An image processing algorithm is presented to reconstruct optical pathlength distributions from images of nonabsorbing weak phase objects, obtained by a differential interference contrast (DIC) microscope, equipped with a charge-coupled device camera. The method is demonstrated on DIC images of transparent latex spheres and unstained bovine spermatozoa. The images were obtained with a wide-field DIC microscope, using monochromatic light. After image acquisition, the measured intensities were converted to pathlength differences. Filtering in the Fourier domain was applied to correct for the typical shadow-cast effect of DIC images. The filter was constructed using the lateral shift introduced in the microscope, and parameters describing the spectral distribution of the signal-to-noise ratio. By varying these parameters and looking at the resulting images, an appropriate setting for the filter parameters was found. In the reconstructed image each grey value represents the optical pathlength at that particular location, enabling quantitative analysis of object parameters using standard image processing techniques. The advantage of using interferometric techniques is that measurements can be done on transparent objects, without staining, enabling observations on living cells. Quantitative use of images obtained by a wide-field DIC microscope becomes possible with this technique, using relatively simple means.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1365-2818.1997.2570815.xDOI Listing

Publication Analysis

Top Keywords

optical pathlength
12
images wide-field
12
dic microscope
12
pathlength distributions
8
distributions images
8
differential interference
8
interference contrast
8
image processing
8
dic images
8
wide-field dic
8

Similar Publications

Purpose: The purpose of this study was to develop ground-truth histology about contributors to variable fundus autofluorescence (FAF) signal and thus inform patient selection for treating geographic atrophy (GA) in age-related macular degeneration (AMD).

Methods: One woman with bilateral multifocal GA, foveal sparing, and thick choroids underwent 535 to 580 nm excitation FAF in 6 clinic visits (11 to 6 years before death). The left eye was preserved 5 hours after death.

View Article and Find Full Text PDF

We present the first controlled-environment measurements of the optical path-length change response of telecommunication submarine cables to active seismic and acoustic waves. We perform the comparison among integrated (optical interferometry) and distributed (distributed acoustic sensing, DAS) fibre measurements and ground truth data acquired by 58 geophones, 20 three-axis seismometers and 7 microphones. The comparison between different seismic acquisition methods is an essential step towards full validation and calibration of the data acquired using novel cable-based sensing techniques.

View Article and Find Full Text PDF

We propose an overview of the Rytov approximation in diffuse optics of biological tissues, for the inverse and forward problems. First, we show a physical interpretation of the Rytov approximation as a type of partial pathlength (named fluence rate partial pathlength) which is distinct from the usual partial pathlength for reflectance measurements. Second, we study the accuracy of the Rytov approximation for the calculation of Jacobians considering absorption perturbations and reflectance measurements.

View Article and Find Full Text PDF

Significance: Reference cerebral near-infrared spectroscopy (NIRS) data on the pediatric population are scarce, and in most cases, only cerebral oxygen saturation ( ) measured by continuous wave spatially resolved spectroscopy NIRS is reported. Absolute data for baseline optical and hemodynamic parameters are missing.

Aim: We aimed at collecting baseline cerebral optical parameters [absorption coefficient, ; reduced scattering coefficient, ; differential pathlength factor (DPF)] and hemodynamic parameters [oxy-hemoglobin content ( ), deoxyhemoglobin content (HHb), total hemoglobin content (tHB), ] in a large cohort of pediatric patients.

View Article and Find Full Text PDF

To address many of the deficiencies in optical neuroimaging technologies, such as poor tempo-spatial resolution, low penetration depth, contact-based measurement, and time-consuming image reconstruction, a novel, noncontact, portable, time-resolved laser speckle contrast imaging (TR-LSCI) technique has been developed for continuous, fast, and high-resolution 2D mapping of cerebral blood flow (CBF) at different depths of the head. TR-LSCI illuminates the head with picosecond-pulsed, coherent, widefield near-infrared light and synchronizes a fast, high-resolution, gated single-photon avalanche diode camera to selectively collect diffuse photons with longer pathlengths through the head, thus improving the accuracy of CBF measurement in the deep brain. The reconstruction of a CBF map was dramatically expedited by incorporating convolution functions with parallel computations.

View Article and Find Full Text PDF