Signs of microdislocation of an endocardial electrode (EE) were observed in 56 (14.4%) of 390 patients with an implantable pacemaker in the postoperative period. The microdislocation was diagnosed from electrocardiographic evidence for no response of a pacing pulse and from fluctuations in the pacing threshold, and from X-ray findings of the thickened and ill-defined outlines of a distal EE with preserving cardiac stimulation. The microdislocation preserves high parameters, as evidenced by a PM-20 M digital analyzer.
Download full-text PDF |
Source |
---|
Heart Rhythm
December 2024
School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Background: Electrocardiographic imaging (ECGi) is a noninvasive technique for ventricular tachycardia ablation planning. However, it is limited to reconstructing epicardial surface activation. In silico pace mapping combines a personalized computational model with clinical electrocardiograms (ECGs) to generate a virtual 3-dimensional pace map.
View Article and Find Full Text PDFJACC Clin Electrophysiol
November 2024
Department of Cardiology, Institute of Science Tokyo, Tokyo, Japan.
Background: Conventional endocardial mapping cannot fully elucidate Marshall bundle (MB)-related atrial tachycardia (AT).
Objectives: This study aimed to clarify the clinical and electrophysiological characteristics of MB-related AT definitively diagnosed using catheter insertion.
Methods: Forty-eight patients with AT who had previously undergone mitral isthmus ablation were enrolled in this study.
J Postgrad Med
October 2024
Department of Cardiology, P.D. Hinduja Hospital, Mumbai, Maharashtra, India.
JACC Clin Electrophysiol
January 2025
Cardiac Pacing Unit, Cardiology Department, University Hospital of Geneva, Geneva, Switzerland.
Background: Left bundle branch area pacing (LBBAP) has gained increased adoption globally with the use of both lumenless leads (LLLs) and stylet-driven leads (SDLs). As these leads have been developed for conventional endocardial pacing sites, concerns remain regarding the lead integrity with LBBAP.
Objectives: This study evaluates lead integrity of pacing leads used for LBBAP in a large, real-world cohort of patients with LBBAP.
Isr Med Assoc J
November 2024
Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheva, Israel, Department of Cardiology, Samson Assuta Ashdod University Hospital, Ashdod, Israel.
Background: Cardiac implantable electronic devices (CIEDs) with endocardial leads crossing the tricuspid valve can lead to or worsen tricuspid regurgitation (TR), causing substantial morbidity and mortality. Despite a recent randomized controlled study revealing a low short-term incidence of device-related TR (DRT) post-CIED implantation, uncertainties persist regarding the efficacy of intra-procedural 2-dimensional transthoracic echocardiography (2DTTE) in preventing long-term TR.
Objectives: To conduct a long-term follow-up study on patients with CIED implants based on a previous study conducted at our hospital.