The paper presents experience in clinically testing a digital low-dose X-ray apparatus. X-ray studies were performed in 169 patients: 140 with cardiovascular abnormalities and 19 with lung diseases. The findings show the high quality of images of thoracic aorta and lung structures. The radiation dose received during an examination is many times lower than at routine X-ray study and fluorography, which makes it possible to use the apparatus in mass surveys of contingents at risk for tuberculosis.
Download full-text PDF |
Source |
---|
BMC Cardiovasc Disord
January 2025
Department of Computed Tomography and Magnetic Resonance, Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
Objectives: This study aimed to evaluate the feasibility and accuracy of non-electrocardiogram (ECG)-triggered chest low-dose computed tomography (LDCT) with a kV-independent reconstruction algorithm in assessing coronary artery calcification (CAC) degree and cardiovascular disease risk in patients receiving maintenance hemodialysis (MHD).
Methods: In total, 181 patients receiving MHD who needed chest CT and coronary artery calcium score (CACS) scannings sequentially underwent non-ECG-triggered, automated tube voltage selection, high-pitch chest LDCT with a kV-independent reconstruction algorithm and ECG-triggered standard CACS scannings. Then, the image quality, radiation doses, Agatston scores (ASs), and cardiac risk classifications of the two scans were compared.
J Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
BMC Cancer
January 2025
Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, 450052, China.
Background: An increase in the prevalence of lung cancer that is not smoking-related has been noticed in recent years. Unfortunately, these patients are not included in low dose computer tomography (LDCT) screening programs and are not actually considered in early diagnosis. Therefore, improved early diagnosis methods are urgently needed for non-smokers.
View Article and Find Full Text PDFRadiology
January 2025
From the Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029 (Y.Z., D.F.Y., C.I.H.); and Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China (Y.Z.).
Lung cancer is the leading cause of cancer deaths globally. In various trials, the ability of low-dose CT screening to diagnose early lung cancers leads to high cure rates. It is widely accepted that the potential benefits of low-dose CT screening for lung cancer outweigh the harms.
View Article and Find Full Text PDFNan Fang Yi Ke Da Xue Xue Bao
January 2025
School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
Objectives: We present a new low-dose CT reconstruction method using sub-pixel and anisotropic diffusion.
Methods: The sub-pixel intensity values and their second-order differences were obtained using linear interpolation techniques, and the new gradient information was then embedded into an anisotropic diffusion process, which was introduced into a penalty-weighted least squares model to reduce the noise in low-dose CT projection data. The high-quality CT image was finally reconstructed using the classical filtered back-projection (FBP) algorithm from the estimated data.