We evaluated the insertion characteristics and complications of a new spinal needle 26-gauge Atraucan (group A) compared with 27-gauge Whitacre (group W) in 100 patients undergoing orthopedic surgeries of the lower extremities. Spinal anesthesia was performed in the lateral decubitus position and 0.40-0.5% tetracaine 1.6-2.5 ml was injected through the L 3/4 or L 4/5 interspace. The tactile appreciation of dural presentation with the needle (dural click) was higher in group W (89.8%) than in group A (42.6%) which the back flow of cerebrospinal fluid was not recognized within three punctures was in 2 cases (4%) in group A and in 1 case (2%) in group W. In these 3 cases, spinal anesthesia was performed easily using 25-gauge Whitacre. In group A, the spinal needle could be inserted without using an introducer in 35 cases (70%). The incidence of the postoperative headache or back pain was low and postdural puncture headache (PDPH) did not occur in both groups. We conclude that 26-gauge Atraucan can be handled easily and useful for preventing PDPH.
Download full-text PDF |
Source |
---|
Sensors (Basel)
December 2024
Surgical Performance Enhancement and Robotics (SuPER) Centre, Department of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.
The epidural injection is a medical intervention to inject therapeutics directly into the vicinity of the spinal cord for pain management. Because of its proximity to the spinal cord, imprecise insertion of the needle may result in irreversible damage to the nerves or spinal cord. This study explores enhancing procedural accuracy by integrating a telerobotic system and augmented reality (AR) assistance.
View Article and Find Full Text PDFEur Spine J
January 2025
Department of Neurosurgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang Province, China.
Background: Spinal epidural arachnoid cysts (SEACs) are rare, non-neoplastic pathologies that can cause compressive myelopathy. Preoperative identification of the exact fistula location is crucial for minimally invasive management.
Methods: This single-center retrospective study included 27 patients with SEACs who underwent "double-needle puncture myelography" to precisely localize the fistula before minimally invasive surgery.
J Anaesthesiol Clin Pharmacol
March 2024
Department of Anaesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India.
J Orthop Translat
January 2025
Department of Orthopaedics, The First Affiliated Hospital of Nanjing Medical University, 300 Guangzhou Rd, Nanjing, 210029, China.
Cureus
November 2024
Aerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!